http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
치료용 방사선의 입사각에 따른 광섬유 방사선량계의 체렌코프 빛 측정 및 분석
장경원,조동현,유욱재,신상훈,서정기,이봉수,박병기,문주현 제주대학교 방사선응용과학연구소 2008 방사선응용과학연구소논문집 Vol.22 No.-
In this study, we have measured scintillating light generated in a fiber-optic dosimeter by high energy photon and electron beams using a charge-coupled device. The intensity of Cerenkov lights are also measured and characterized as functions of incident angles and energies of the high energy beams from a clinical linear accelerator. To minimize or remove Cerenkov light, a simple subtraction method using a background optical fiber and wavelength discrimination method using optical filters are investigated. Also, the intensities of Cerenkov light induced by high energy photon and electron beams are compared.
2급 응급구조사의 성인외상환자에 대한 처치의 적절성 평가
장문수,어은경,김상현,김창섭,송근정,박한규,유지영,최동섭 대한응급의학회 1995 대한응급의학회지 Vol.6 No.2
In Korea, EMT have two classified subgroup of first and second degree : EMT-P, and EMT. For the beginning, authorization of the first EMT was made in this year through the EMT educational program. There are 8 items which EMT can perform the treatment without the supervision by a physician. But there was no previous report of pertinent assesment of treatment performed by the EMT. There upon authors have conducted review of assessment done by the EMT in EC setting, and proposed the following treatment application can be used by EMT at the field of accident. The study materials include adult trauma patient older than 15 years, and sustained trauma within 48 hours before visiting Ewha University DongDaeMoon Hospital Emergency Deparment. The duration of study was from Apr. 1 1995 to Aug. 31 1995. the study was conducted by 5 certified EMT. The EMT's performance was evaluated by the attending Emergency Medicine physician. The result were as followings ; 1. Among the total 5532 ED visiting patients during the study period, 1267 were adult trauma patients who recieved treatment within 48 hours of injury. 2. Among 1222 out of 1267 patients have completed performed survey. 3. Male to female ratio was 2.6 : 1, age distribution was from 15 to 87 years old and mean age was 34.6 years old. 4. The MOI showed : MVA (33.1%), blunt trauma (29.9%), slip down (16.8%), penetrating injury(15.4%), and miscellaneous (5.7 %), burn (3.1%), falling down injury(2.9 %), bite injury(1.1%) in order. 5. There were 437 cases of survey completed by the EMT. For assessment of mental status of 3 different method : AVPU, 5 scale mental status and GCS, were correlated with EM physician with 99.1%, 98.6%, 97.7 %, respectively. 6. For 320 out of 437 cases of survey completed, 319 patients recieved treatment by the EMT within 30 minute and 1 patient between 30 to 60 minute of an ED arrival. 7. For those 437 cases of survey completed, 266 patient (60.9%) had adequate treatment and 54 patients (12.4%) had inadequate treatment. 67 patient (15.3%) did not received treatment but it was adequate inway, and 50 patients (11.9%) did not received treatment even though patient required treatment. In cases of adult trauma patients, EMT's mental status assessment was correlated with EM physician's assessment. But treatment done by EMT without the supervision of EM physician was adequate only in 76.2 %. Therefore, continuous education and assessment of treatment performed by EMT in needed to improve field treatment by EMT future.
이동민,장경식,양종태,장대용,김종오,서영욱,고영엽,홍순표 조선대학교 부설 의학연구소 2002 The Medical Journal of Chosun University Vol.27 No.1
Background: The sigmoid septum described an anatomical variation in the contour of the left ventricular outlet. It is related to degenerative change with aging. We observed clinical significance of sigmoid septum in Korean. Methods: Echocardiographic examination was performed in 434 patients. Sigmoid septum is defined as discrete bulging of the proximal interventricular septum with that thickness is greater than 1.3cm or the thickness is grater 1.5 times than adjacent mid interventricular septum in apical 3 chamber view. Result: The incidence of patient with sigmoid septum(septum patient) is 24.8% (male 8.4%, female 16.3%) . The incidence increases with age and is more common in women. The patients with sigmoid septum were compared with targeted groups, there was no significant difference in blood pressure between them, but in height and weight, the former were lower. (p<001, p<03). In the patients with sigmoid septum, weight and the surface area of a body have an opposite correlation with increase of age (p<03, r=-0.34) (p<04, r=-0.31) , but no decrease of height was found according to age increase (p=0.47, r=-0.11) The main reason patients with sigmoid septum ask echocardiolography and its clinical symptoms were abnormal results of previous electrocardiography and/or usual chest pain. Compared with control group, interventricular septal thickness is larger in septum patients (p<001). The thickness of interventricular septum located in subaortic left ventricular outflow tract is 1.6±0.3cm. There is another web like structure that continued from interventricualr septum to anterior free wall of left ventricle and the width is 1.6±0.4cm. A sign of insignificant obstruction due to left ventricular outflow was observed from three sigmoid septum patients. Conculusion: Septum patient is largely found in older age group and the body weight and body surface area are lower than control group. The body weight and body surface area are opposite correlation with age. So sigmoid septum is considered as structural change by weight reduction with aging. It is assumed that septum patients are related with asymptomatic ischemia because they have more abnormal ECG finding such as T wave inversion on precordial leads or standard leads, nonspecific ST-T change, LBBB etc. Sigmoid septum is not only proximal interventricular septal bludging but also another web like structure continuing to anterior wall of left ventricle.
광섬유 방사선 센서와 EBT 필름을 이용한 심부선량 백분율 측정 및 비교
조동현,장경원,유욱재,신상훈,이봉수,문주현,박병기 제주대학교 방사선응용과학연구소 2008 방사선응용과학연구소논문집 Vol.22 No.-
In this study, fiber-optic sensor is fabricated to measure PDD of CLINAC. As a scintillating light generated by a high energy X-ray from the medical LINAC is measured using photo diode amp system, It is expected that a high-resolution, real-time fiber-optic dosimeter for medical LINAC can be developed.
광섬유 집합체 센서를 이용한 6MV 광자선의 반음영 및 심부선량백분율 측정
신상훈,장경원,조동현,유욱재,서정기,이봉수,문주현,박병기 제주대학교 방사선응용과학연구소 2008 방사선응용과학연구소논문집 Vol.22 No.-
In this study, a fiber-optic bundle sensor has been developed using water-equivalent organic scintillating fibers for photon beam measurement. Beam penumbra and percent depth doses(PDD) are measured according to the depth of the photon beam. This sensor has many advantages such as high resolution, real-time measurement and ease of calibration over conventional radiation measurement devices.
방사성 페기물 처리장의 지하수 온도 측정을 위한 광섬유 센서의 제작 및 특성 분석
서정기,유욱재,장경원,조동현,신상훈,이봉수 제주대학교 방사선응용과학연구소 2008 방사선응용과학연구소논문집 Vol.22 No.-
Fiber-optic temperature sensing technology can alternative to classical measurement techniques in nuclear environment, Its advantages allow low cost, a long distance measurement and real-time, In this study, we have measured the optical power of power meter and the output voltage of photodiode according to change temperature of water.
Kyoung Won Jang,Man Woo Lee,Heuijin Lim,Sang Koo Kang,Sang Jin Lee,Seung Heon Kim,Dong Eun Lee,Hee Chang Kim,Dong Hyeok Jeong 한국물리학회 2020 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.76 No.7
A uniform electron field is required for medical applications of electron linear accelerators (LINACs). Electron irradiation devices, including scattering foils and applicators for generating uniform electron fields, are widely used in medical LINACs. In this research, an electron scattering device consisting of scattering foils and applicators was designed for clinical application of a 9-MeV electron LINAC planned at the Dongnam Institute of Radiological & Medical Sciences. Monte Carlo simulations were performed to calculate the depth dose and the beam profile curves in a water phantom by using the EGSnrc Monte Carlo code.