RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • 미생물 증식 공정에서의 새로운 기질 저해 모델 : Hwang 모델의 응용 Applications of Hwang Model

        황영보 국립7개대학공동논문집간행위원회 2002 공업기술연구 Vol.2 No.-

        A new biokinetic model, named Hwang model, has been considered to account for the substrate inhibitory effects in microbial growth processes. Its main advantage is flexibility, i.e. its ability to fit experimental data which corresponds to diverse inhibition patterns including concave, convex, and linear as well as linear decrease with inhibition-threshold. Performances are compared on the basis of the goodness of fit and the best-fittings of different experimental data in the literature, respectively. Finally, Hwang model turns out to be flexible enough for the overall validation of microbial substrate inhibition phenomena.

      • KCI등재후보

        Continuous Wave of Condensation Technique으로 근관충전시 치근면 온도상승 분석

        김영주,황윤찬,김선호,황인남,최보영,정영진,정우남,오원만 大韓齒科保存學會 2003 Restorative Dentistry & Endodontics Vol.28 No.4

        This study was conducted to evaluate the temperature rise on the root surface while the root canal is being obturated using continuous wave of condensation technique. Maxillary central incisor was prepared for repeated canal obturation. Ten thermocouples (Omega Engineering Inc., Stanford, USA) were placed at 1mm increment from the anatomical root apex. The real temperature of Buchanan plugger was recorded before insertion into the root canal. The root canal was obturated with continuous wave of condensation technique as described by Buchanan and the root surface temperature was recorded during obturation at 150℃, 200℃, 250℃ and 300℃ temperature settings of System B HeatSource (Model 1005, Analytic technologies, Redmond, WA, USA). After completion of the temperature recording, the dentinal-cementum thickness at each sites was measured. The data were analyzed using one-way ANOVA followed by Scheffe's test and linear regression test. The results were as follows. 1. When the temperature was set at 150℃, 200℃, 250℃ and 300℃ on the digital display of System B HeatSource, the real temperature of the plugger at the 1mm point from the tip revealed 130.82±2.96℃ 158.00±5.26℃, 215.93±6.91℃ and 249.88±3.65℃ respectively. 2. The position of 8 mm from the anatomical apex showed the highest temperature increase at each temperature settings and it was significantly higher than those of other positions (p<0.01). The temperature rise was constantly increased toward coronal portion from apex of the root. 3. The maximum temperature increase on the root surface was 2.37±0.09℃ at 150℃ setting, 3.11±0.12℃ at 200℃ setting, 3.93±0.09℃ at 250℃ setting and 5.69±0.15℃ at 300℃ setting respectively. These results suggest that it be relatively kind to the supporting tissues of the root that the root canal is obturated using continuous wave of condensation technique at 150℃, 200℃, 250℃ and 300℃ temperature settings on digital temperature display of System B HeatSource.

      • Continuous Wave of Condensation Technique으로 근관충전시 치근면 온도상승 분석

        김영주,황윤찬,김선호,황인남,최보영,정영진,정우남,오원만 전남대학교 치의학연구소 2003 구강과학 Vol.15 No.4

        This study was conducted to evaluate safety to the supporting tissues of the root while the root canal is obturated using continuous wave of condensation technique. A extracted maxillary central incisor was prepared for repeated canal obturation. After conventional access opening, working length was then established to the point 1㎜ from anatomical root apex. The root canal was prepared with GT rotary Ni-Ti file (Dentsply Maillefer, Switzerland). Five thermocouples (Onega Engineering Inc., USA) were placed at 2㎜ increments on one side beginning 1㎜ from the anatomical root apex and the other five thermocouples at 2㎜ increments on the other side beginning 2㎜ from it. For obturation, a nonstandardized medium size gutta-percha cone and a ML Buchanan plugger (Analytic technologies, USA) were selected. After drying of root canal, AH 26 root canal sealer (Dentsply Detrey, Germany) was applied on the wall of the root canal. Baseline temperature was measured on the root surface. The ML size plugger was preheated for 2seconds and then the real temperature of it was recorded before insertion into the root canal. The root canal was obturated with continuous wave of condensation technique as described by Buchanan. The root surface temperature was recorded during obturation and it was performed ten times at each of the following temperature settings: 150℃, 200℃, 250℃ and 300℃. After completion of the temperature recording, the dentinal-cementum thickness at each sites where thermocouples were attached was measured. The data were analyzed using one-way ANOVA followed by Scheffe's test and linear regression test. The results were as follows. 1. When the temperature was set at 150℃, 200℃, 250℃ and 300℃ on the digital display of System B HeatSource, the real temperature of the plugger at the 1㎜ point from the tip revealed 130.82±2.96℃, 158.00±5.26℃, 215.92±6.91℃ and 249.88±3.65℃ respectively. 2. The position of 8 ㎜ from the anatomical apex showed the highest temperature increase at each temperature settings and it was significantly higher than those of other positions (p<0.01). The temperature rise was constantly increased toward coronal portion from apex of the root. 3. The maximum temperature increase on the root surface was 2.37±0.09℃ at 150℃ setting, 3.11±0.12℃ at 200℃ setting, 3.93± 0.09℃ at 250℃ setting and 5.69± 0.15℃ at 300℃ setting. These results suggest that it be relatively kind to the supporting tissues of the root that the root canal is obturated using continuous wave of condensation technique at 150℃, 200℃, 250℃ and 300℃ temperature settings on digital display of System B HeatSource.

      • 연폭로 근로자들에서 빈혈증 관련 인자에 관한 연구

        황보영,김용배,김화성,이성수,안규동,이병국 순천향대학교 교수학습개발센터 2004 Journal of Soonchunhyang Medical Science Vol.10 No.3

        Objectives : This study intended to obtain the interrelationship of lead exposure indices and anemia related factors for the better health management of lead exposed workers. Methods : 502 male workers in storage battery industries as lead exposed group and 106 male office workers as contorl group were selected for this study. The examined variables wer age, work duration, smoking and alcohol crinking habit, blood zinc protoporphyin concentraion (ZPP), blood lead concentration (PbB), urinary δ-aminoevulinic acid (ALAU), hemoglobin (Hb), hematocrit (Hct), serum calcium (S-Ca), serum iron (S-Fe), total iron binding capacity (TIBC), and percentage trasferrin saturation (PTS). Results : The means of ZPP, PbB ALAU in lead exposed proup were 58.4±35.7 ㎍/㎗, 27.6±10.9 ㎍/㎗, and 1.61±2.00 mg/ℓ, respectively. These three values in lead exposed group were significantly higher than control group (P<.05). The means of Hb, Hct, S-Ca, S-Fe, TIBC, PTS in lead exposed group were 15.3±1.1 g/㎗, 47.2±4.5 %, 9.4±0.4 ㎍/㎗, 124.0±67.5 ㎍/㎗, 317.1±68.5 ㎍/㎗, and 38.7±15.2 %, respectively. Hb, Hct, S-Ca, S-Fe, and TIBC in lead exposed group were significantly lower than contrl group (P<.05). PTS was no significant difference in lead exposed group and control group (P> .05). Hct, S-Ca, S-Fe, PTS were significant positive correlation with Hb and ZPP, corrected PbB, AlAU were significant negaitive correlation with Hb in lead exposed group (P< .05). On multiple regression using ZPP as a dependent variable and PbB, S-Ca and S-Fe as independent variables after adjustment for possible confounder such as age, smoking and drinking habit, Pbb, S-Ca, S-Fe and age contributed to ZPP. Conclusions : As the result of this study, it was suggested that inclusion of S-Ca, S-Fe, PTS measurement as a anemia screening test for lead workers was highly recommended for the effective prevention and early diagnosis of anemia.

      • 심한 비선형적 미생물 증식 공정에 대한 일반화된 생물 동특성 모델 : Part 1. Button 접근법의 도입 Part1. Introduction of Button's approach

        황영보 국립7개대학공동논문집간행위원회 2004 공업기술연구 Vol.4 No.-

        Based on the biokinetic model for the substrate inhibition developed in these serial studies, a modeling study has been also carried out to account not only for the nonlinear substrate limitation effects but also for the substrate inhibition. For the compensation of the low substrate limitation effect, Button's approach, ie. the concept of a threshold substrate concentration, is introduced in several models for substrate inhibition. The performance of these generalized microbial growth models is compared on the basis of goodness of fit and best-fitting of the available data in the literature.

      • 순천향의과대학 졸업생의 학부성적과 의사국가고시 성적의 관련성

        황보영 순천향대학교 교수학습개발센터 2004 Journal of Soonchunhyang Medical Science Vol.10 No.3

        Objectives: This study analysed the correlation between grade point average (GPA) of medical school and the score of Korean Medical Licensing examination(KMLE). Methode: This study based on the result of the KMLE applicants who graduated from a college of medicine in 2003 and 2004. We also gathered data of these applicants from the college of medicine : gender, age, type of entrance, period of attendance, GPA of basic medicine, clinical medicine, clinical clerkships and final test scores. We analyed whether these variables affected the results of KMLE. Results: 184 applicants (90.6%) passed KMLE among 203. In the logistic regression test, GPAs of clinical medicine and final test scores were significant variables on the results of KMLE, after adjustment of covariates. Cut-off points of high risk group for failing KMLE were below 76.0(sensitivity 90; specificity 80; positive predictive value 32), 78.0(sensitivity 79; specificity 90; positive predictive value 46), 77.2(sensitivity 90; specificity 88; positive predictive value 43), 72.8(sensitivity 90; specificity 88; positive predictive value 44) in the GPAs of basic medicine, clinical medicine, clinical clerkships and final test scores, respectively. Conclusions: There were signficant associaton between the GPAs of clinical medicine and final test scores and the results of KMLE. High-risk groups of failing KMLE were the students whose GPA of baisc medicine were below 78.0, GPA of clinical clerkships were below 77.2 and final test score were below 72.8.

      • 개선된 Haldane 모델의 이론적 접근

        황영보 국립7개대학공동논문집간행위원회 2001 공업기술연구 Vol.1 No.-

        This paper deals with the theoretical derivation of the modified Haldane model in the microbial growth processes. Based on the biological concepts of substrate-receptor and inhibitor-receptor working mechanisms, a new N-fold non-competitive microbial inhibition mechanism has been considered, which is natural expansion of the single non-competitive inhibition in the enzyme reaction. Finally, modified Haldane model turned out to be well designed with a biological meaningful constant of total inhibition concentration.

      • KCI등재
      • KCI등재

        우울장애 환자에서 자살 시도와 트립토판 수산화 효소(Tryptophan Hydroxylase) A218C 유전자 다형성과의 관련성

        심세훈,황보영,권영준,정희연,이분희,김용구 대한신경정신의학회 2008 신경정신의학 Vol.47 No.2

        Objectives : Several lines of evidence suggest the serotonergic dysfunction involved in the biological susceptibility of suicide. Tryptophan hydroxylase (TPH), the rate-limiting enzyme in the biosynthesis of serotonin, Plays a vital role in serotonin metabolism. In a case-control study, we investigated whether the TPH gene was a susceptible factor for suicidal behavior in depressive patients. Methods : The subjects were 218 depressed patients who attempted suicide and visited emergency rooms in multi-medical centers. One hundred thirty hospitalized non-suicidal depressed patients and the 161 normal controls were matched with the suicidal group. Individuals in all 3 groups were evaluated independently by a Structured Clinical Interview for the purpose of establishing a DSM-IV criteria diagnosis (SCID). The severity of depressive symptoms was evaluated using Hamilton depression rating scale (HDRS). Results : There was no significant difference in genotype distributions and allele frequencies of TPH intron 7 A218C polymorphisms among 3 groups. Furthermore, no significant difference in genotype counts and allele frequencies of the polymorphisms was found among lethal suicidal depressed patients, non-suicidal depressed patients and the normal controls. Conclusion : This study suggests that the A218C polymorphism of the TPH gene is unlikely to have a major effect on the susceptibility of suicidal behaviors in depressive patients.

      • KCI등재후보

        열전대(thermocouple)를 이용한 Buchanan Plugger 표면의 온도상승 분석

        조진숙,황윤찬,김선호,황인남,최보영,정영진,정우남,오원만 大韓齒科保存學會 2003 Restorative Dentistry & Endodontics Vol.28 No.4

        This study was performed to evaluate the actual temperature rise on the surface of Buchanan plugger using thermocouple. The heat carrier system 'System B Heatsource'(Model 1005, Analytic Technologies, Redmond, WA, USA) and the Buchanan pluggers of F, FM, M and ML sizes are used for this study. The temperature was set to 200℃ on digital display and the power level on it was set to 10. Five thermocouples were placed in direct contact with the surface of each size of Buchanan's pluggers at 1 mm increments from the tip to the 4 mm length of shank. The heat control spring was touched for 5 seconds, and temperature rise on the surface of the pluggers were measured at 1 sec intervals for more than 5 seconds with an accuracy of 0.01 using Data Logger. The data were statistically analyzed by one-way ANOVA. The results were as follows. 1. The position at which the temperature peaked was approximately at 1~2 mm far from the tip of Buchanan plugger (p<0.01). 2. The peak temperature was 215.25±2.28℃ in F plugger, 185.94±2.19℃ in FM plugger, 169.51±9.12℃ in M plugger, and 160.79±1.27℃ in ML plugger and the peak temperature was highest in F plugger and followed by, in descending order, FM plugger, M plugger. ML plugger showed the lowest peak temperature (p<0.01). 3. The temperature on the pluggers was decreased with the increase of touching time. This results suggest that the actual temperature on the surface of the pluggers dose not correlate well with the temperature set on digital display. Heat concentrates around the up. The larger plugger reveals lower temperature rise relatively.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼