http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
R134a 및 Rl23과 비공비 혼합냉매 R134a/R123의 수평관내 이상유동양식에 관한 연구
임태우,김준효,Lim, Tae-Woo,Kim, Jun-Hyo 대한기계학회 2003 大韓機械學會論文集B Vol.27 No.8
Two-phase flow pattern data during horizontal in-tube flow boiling are presented for pure and mixed refrigerants of R134a and Rl23, The flow pattern is observed through tubular sight glasses located at inlet and outlet of the test section, which is made of a stainless steel tube, 2m long with 10mm I.D., 1.5mm wall thickness. The obtained results are compared with the available various correlations for flow pattern. The flow pattern map of Hashizume was in good agreement with the present data except the region of low mass velocity. Weisman flow pattern map was also known to satisfactorily predict data for refrigerants in the region of annular flow. In this study, the flow pattern are simply classified into two groups; stratified(including intermittent, stratified and stratified-wavy) flow and annular flow. The transition quality from stratified to annular flow was obtained by modifying the liquid Froude number.
임태우,최재혁,김준효,최용석,Lim, Tae-Woo,Choi, Jae-Hyuk,Kim, Jun-Hyo,Choi, Yong-Suk 해양환경안전학회 2012 海洋環境安全學會誌 Vol.18 No.5
$500{\mu}m$의 수력직경을 가진 마이크로 채널에서 유동 비등 시 물에 대한 마찰 압력 강하를 측정하기 위한 실험적 연구를 수행하였다. 실험은 열 유속 $100-400kW/m^2$, 증기건도 0-0.2 그리고 질량 유속 $200-600kg/m^2s$의 범위에서 이루어졌다. 유동 비등 시 마찰 압력 강하는 두 가지 모델을 사용하여 예측된다. 즉, 두 상의 속도가 동일하다고 가정한 균질 모델과 두 상 사이에 서로 다른 속도를 가지는 분리류 모델로 분류된다. 실험결과 이상 마찰 승수는 질량 유속이 증가함에 따라 감소한다는 것을 알 수 있었다. 측정된 압력 강하 데이터는 매크로 스케일과 미니/마이크로 스케일에서 제안된 기존의 여러 상관식들과 비교하였다. 균질 모델은 본 연구에서 고려한 실험 조건에서 29.4 %의 평균 오차내에서 마찰 압력 강하를 예측하였다. An experimental study was carried out to measure frictional pressure drop in flow boiling to deionized water in a microchannel having a hydraulic diameter of $500{\mu}m$. Tests were performed in the ranges of heat fluxes from 100 to $400kW/m^2$, vapor qualities from 0 to 0.2 and mass fluxes of 200, 400 and $600kg/m^2s$. The frictional pressure drop during flow boiling is predicted by using two models; the homogeneous model that assumes equal phase velocity and the separate flow model that allows a slip velocity between two phases. From the experimental results, it is found that the two phase multiplier decreases with an increase in mass flux. Measured data of pressure drop are compared to a few available correlations proposed for macroscale and mini/microscale. The homogeneous model well predicted frictional pressure drop within MAE of 29.4 % for the test conditions considered in this work.
수평 전열관내 비공비 혼합냉매 R134a/R123의 강제대류비등 열전달에 관한 연구
임태우,한규일,Lim, Tae-Woo,Han, Kyu-Il 대한기계학회 2003 大韓機械學會論文集B Vol.27 No.3
An experimental study was carried out to measure the heat transfer coefficient in flow boiling to mixtures of HFC-l34a and HCFC-123 in a uniformly heated horizontal tube. Tests were run at a pressure of 0.6 MPa and in the ranges of heat flux 1-50 kw/$m^2$, vapor quality 0-100 % and mass velocity 150-600 kg/$m^2$s. Heat transfer coefficients of mixture were less than the interpolated values between pure fluids both in the low quality region where the nucleate boiling is dominant and in the high quality region where the convective evaporation is dominant. Measured data of heat transfer are compared to a few available correlations proposed for mixtures. The correlation of Jung et. al. satisfactorily predicted the present data, but the data in lower quality was overpredicted and underpredicted the high quality data. The correlation of Kandlikar considerably underpredicted most of the data. and showed the mean deviation of 35.1%.
다공형 전열판의 회전에 의한 열교환시스템의 성능에 관한 연구
임태우(T. W. Lim),조동현(D. H. Cho) 한국동력기계공학회 2005 한국동력기계공학회 학술대회 논문집 Vol.- No.-
The experimental investigation was carried out to evaluate the performance of air-to-air heat exchanger with rotating porous plates newly developed in this study. The rotating porous plates are mounted with an equal interval of 18 ㎜ inside the heat exchanger where the hot and cold airs enter at opposite ends. When flowing in opposite directions by the separating plate installed in the center of the rotating porous plates, the airs give and receive the heat each other. The material of the porous plate is cooper and its thickness is 1.0 ㎜. Air flow rate is varied from 10 to 120 ㎥/h. From the experiment of air-to-air heat exchanger with the rotating porous plates, the heat exchange performance increased with the increase in RPM of the porous rotating discs at the conditions of the same air flow rate. The sensible heat exchange efficiency was maximum 60 to 70 percent, and enthalpy exchange efficiency 50 to 60 percent.