RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        The Image Quality and Radiation Dose of 100-kVp versus 120-kVp ECG-Gated 16-Slice CT Coronary Angiography

        박은아,강진화,인용후,정진욱,박재형,이활 대한영상의학회 2009 Korean Journal of Radiology Vol.10 No.3

        Objective: This study was conducted to assess the feasibility of performing 100-kVp electrocardiogram (ECG)-gated coronary CT angiography, as compared to 120-kVp ECG-gated coronary CT angiography. Materials and Methods: We retrospectively evaluated one hundred eighty five gender- and body mass index-matched 16-slice coronary CT sets of data, which were obtained using either 100 kVp and 620 effective mAs or 120 kVp and 500 effective mAs. The density measurements (image noise, vessel density, signal-tonoise ratio [SNR] and contrast-to-noise ratio [CNR]) and the estimated radiation dose were calculated. As a preference test, two image readers were independently asked to choose one image from each pair of images. The results of both protocols were compared using the paired t-test or the Wilcoxon signed rank test. Results: The 100-kVp images showed significantly more noise and a significantly higher vessel density than did the 120-kVp images. There were no significant differences in the SNR and CNR. The estimated reduction of the radiation dose for the 100-kVp protocol was 24%; 7.8 ± 0.4 mSV for 100-kVp and 10.1 ± 1.0 mSV for 120-kVp (p < 0.001). The readers preferred the 100-kVp images for reading (reader 1, p = 0.01; reader 2, p = 0.06), with their preferences being stronger when the subject’s body mass index was less than 25. Conclusion: Reducing the tube kilovoltage from 120 to 100 kVp allows a significant reduction of the radiation dose without a significant change in the SNR and the CNR. Objective: This study was conducted to assess the feasibility of performing 100-kVp electrocardiogram (ECG)-gated coronary CT angiography, as compared to 120-kVp ECG-gated coronary CT angiography. Materials and Methods: We retrospectively evaluated one hundred eighty five gender- and body mass index-matched 16-slice coronary CT sets of data, which were obtained using either 100 kVp and 620 effective mAs or 120 kVp and 500 effective mAs. The density measurements (image noise, vessel density, signal-tonoise ratio [SNR] and contrast-to-noise ratio [CNR]) and the estimated radiation dose were calculated. As a preference test, two image readers were independently asked to choose one image from each pair of images. The results of both protocols were compared using the paired t-test or the Wilcoxon signed rank test. Results: The 100-kVp images showed significantly more noise and a significantly higher vessel density than did the 120-kVp images. There were no significant differences in the SNR and CNR. The estimated reduction of the radiation dose for the 100-kVp protocol was 24%; 7.8 ± 0.4 mSV for 100-kVp and 10.1 ± 1.0 mSV for 120-kVp (p < 0.001). The readers preferred the 100-kVp images for reading (reader 1, p = 0.01; reader 2, p = 0.06), with their preferences being stronger when the subject’s body mass index was less than 25. Conclusion: Reducing the tube kilovoltage from 120 to 100 kVp allows a significant reduction of the radiation dose without a significant change in the SNR and the CNR.

      • KCI등재

        Ultrasound and Fluoroscopy-Guided Placement of Central Venous Ports via Internal Jugular Vein: Retrospective Analysis of 1254 Port Implantations at a Single Center

        안세진,김효철,정진욱,안상부,인용후,제환준,박재형 대한영상의학회 2012 Korean Journal of Radiology Vol.13 No.3

        Objective: To assess the technical success and complication rates of the radiologic placement of central venous ports via the internal jugular vein. Materials and Methods: We retrospectively reviewed 1254 central venous ports implanted at our institution between August 2002 and October 2009. All procedures were guided by using ultrasound and fluoroscopy. Catheter maintenance days, technical success rates, peri-procedural, as well as early and late complication rates were evaluated based on the interventional radiologic reports and patient medical records. Results: A total of 433386 catheter maintenance days (mean, 350 days; range 0-1165 days) were recorded. The technical success rate was 99.9% and a total of 61 complications occurred (5%), resulting in a post-procedural complication rate of 0.129 of 1000 catheter days. Among them, peri-procedural complications within 24 hours occurred in five patients (0.4%). There were 56 post-procedural complications including 24 (1.9%, 0.055 of 1000 catheter days) early and 32 (2.6%, 0.074 of 1000 catheter days) late complications including, infection (0.6%, 0.018 of 10000 catheter days), thrombotic malfunction (1.4%, 0.040 of 1000 catheter days), nonthrombotic malfunction (0.9%, 0.025 of 1000 catheter days), venous thrombosis (0.5%, 0.014 of 1000 catheter days), as well as wound problems (1.1%, 0.032 of 1000 catheter days). Thirty six CVPs (3%) were removed due to complications. Bloodstream infections and venous thrombosis were the two main adverse events prolonging hospitalization (mean 13 days and 5 days, respectively). Conclusion: Radiologic placement of a central venous port via the internal jugular vein is safe and efficient as evidenced by its high technical success rate and a very low complication rate.

      • KCI등재

        간ㆍ담도ㆍ췌장 수술에서 간동맥의 안전한 처리지침 수립을 위한 연구

        양성훈(Sung Hoon Yang),인용후(Yong Hu Yin),장진영(Jin-Young Jang),이승은(Seung Eun Lee),정진욱(Jin Wook Chung),서경석(Kyung-Suk Suh),이건욱(Kuhn Uk Lee),김선회(Sun-Whe Kim) 대한외과학회 2009 Annals of Surgical Treatment and Research(ASRT) Vol.76 No.2

        Purpose: Hepato-pancreatico-biliary (HPB) surgeons often must make decisions regarding hepatic artery (HA) resection while performing major HPB surgery. The purpose of this report was to review and summarize HA resection experience with a focus on vascular preservation during major HPB surgery and to develop a useful algorithm in dealing with these needs. Methods: We reviewed 1,324 cases that had available computed tomographic and angiographic findings and summarized the problematic HA variations encountered in major HPB surgery. In reviewing our series and previous studies, we have created a set of guidelines that enables a pragmatic approach to the unique variations in HA and the risks of cancer invasion. Results: Challenging HA variations during major HPB surgery were found in 25.7% of the cases and included variations of common HA from superior mesenteric artery (SMA), gastroduodenal artery (GDA), aorta, celiaco-mesenteric (CM) trunk or left gastric artery (LGA) (3.70%), the variations of the right HA from SMA, GDA, aorta, celiac axis (CA) including CM trunk or LGA (12.76%), the variations of the left HA from LGA, CA or GDA (4.46%), and the mixed types of the aberrant left medial HA and/or left lateral HA and/or right anterior HA and/or right posterior HA (2.11%). Conclusion: Surgeons should have knowledge of the anatomically variable vasculature of the HA when planning for major HPB surgery. Preoperative imaging studies can aid and should be performed in anticipation of potential HA variations during major HPB surgery.

      • KCI등재

        Transcatheter Arterial Embolization Therapy for a Massive Polycystic Liver in Autosomal Dominant Polycystic Kidney Disease Patients

        박혜인조,김치원,노한,오국환,김연수,이정상,인용후,재환준,정진욱,안규리,황영환,문주영 대한의학회 2009 Journal of Korean medical science Vol.24 No.1

        Polycystic liver is the most common extra-renal manifestation associated with autosomal dominant polycystic kidney disease (ADPKD), comprising up to 80% of all features. Patients with polycystic liver often suffer from abdominal discomfort, dyspepsia, or dyspnea; however, there have been few ways to relieve their symptoms effectively and safely. Therefore, we tried transcatheter arterial embolization (TAE), which has been used in treating hepatocellular carcinoma. We enrolled four patients with ADPKD in Seoul National University Hospital, suffering from enlarged polycystic liver. We embolized the hepatic arteries supplying the dominant hepatic segments replaced by cysts using polyvinyl alcohol particles and micro-coils. The patients were evaluated 12 months after embolization for the change in both liver and cyst volumes. Among four patients, one patient was lost in follow up and 3 patients were included in the analysis. Both liver (33%; 10%) and cyst volume (47.7%; 11.4%) substantially decreased in two patients. Common adverse events were fever, epigastric pain, nausea, and vomiting. We suggest that TAE is effective and safe in treating symptomatic polycystic liver in selected ADPKD patients.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼