이준식,Lee Joon Sik 대한설비공학회 1987 설비저널 Vol.16 No.1
The heat transfer processes taking place in the side wall of a thermocline enclosure have been analyzed for idealized conditions based on the assumption that, at any instant time, side wall heat transfer processses are independent of the thermocline bulk motion. However, the axial tempera-ture distribution in the thermocline core provides the means for specifying the liquid medium-side boundary condition to the enclosure side wall. A picture is drawn which reflects the side wan response to thermocline bulk motion within the frame work of a quasi-steady analytic approach. For valves of the parameters typical of systems of engineering interest, the analysis shows that a significant amount of heat transfer short - circuiting can take place along the side wall enclosure. This phenomenon is favored by high values of $H_l$ and low values of P and $H_g$ respec-tively. The location of the point of zero normal heat flux on the side wan can be expected to mark, approximately, the region of confluence of two sidewall boundary flows respectively driven by the buoyant effects.
LPG Injector 컷솔 유동 특성 및 설계 변수 연구
이준식(Joon Sik Lee),임설(Seol Lim),김상덕(Sang Dug Kim),송동주(Dong Joo Song) 한국전산유체공학회 2008 한국전산유체공학회 학술대회논문집 Vol.2008 No.-
Fluid flow in LPG injector is delayed momently around nozzle and leaked accidentally, then engine operation becomes unstable. When attached cutsole injector that we can prevent fuel from leaking. Attaching additional devices cause loss of power and pressure. In this study, We has analyzed the performance of the LPG injector nozzle by changing cutsole geometry numerously by using Computational Fluid Dynamics.