http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
전기분해에 의해 제조된 NaOCl을 이용한 염색폐수의 처리 특성(I)
윤용수,하범용,노방타잉후이,Yoon, Yong-Soo,Ha, Beom-Yong,Thanh Huy, Ngo Van 한국섬유공학회 2005 한국섬유공학회지 Vol.42 No.5
This study was carried out to investigate the feasibility of using electrolytically generated NaOCl solution for treatment of wastewater containing an acid dye(C.I. Acid Red 114). The NaOCl was produced by the electrolysis of aqueous NaCl solution. In order to asses the treatment characteristics, we evaluated the effect of pH and mixing ratio of the NaOCl solution to colored wastewater on the color and chemical oxygen demand$(COD_{Mn})$ removal. The optimum conditions for the dye and $COD_{Mn}$ removal were determined to be pH 5.0 and mixing ratio of 1 :9, at which more than $88\%$ color and $87\%$ $COD_{Mn}$ were removed within 10 min reaction time. Reaction rate constants for the 300 and 500mg/l of artificially prepared dyeing wastewater were estimated as 0.1764 and $0.1737 min^{-1}$ for color removal and 0.1197 and $0.1436 min^{-1}$ for $COD_{Mn}$ removal, respectively.
황산구리 용액으로부터의 구리회수공정에서 초음파에 의한 전착반응의 증대효과
윤용수,홍인권,이재동,정일현 ( Yoon Yong Soo,Hong In Kwon,Jae Dong Lee,Jeong Il Hyun ) 한국공업화학회 1994 공업화학 Vol.5 No.2
본 연구에서는 초음파의 Cavitation에 의한 혼합효과와 표면세정 효과 그리고 유효 충돌빈도의 중가효과를 이용하여 구리이온을 함유한 용액으로부터 전착반응에 의한 구리의 회수공정에서 전착반응속도를 증가시키고자 초음파 진동자를 직접 반응기 벽면에 부착시킨 반응기를 제작하였다. 초음파 반응저에서 과전압과 황산구리의 농도를 변수로 하여 반응시간에 대한 전류밀도를 측정하고, 음극에 석출된 구리의 양에 의하여 초음파에 의한 반응속도 증가효과에 대하여 연구한 결과 초음파에 의한 효과는 과전압이 2.1V, 황산구리의 농도가 0.1M일 때 석출된 구리의 양이 초음파를 가하지 않은 반응기에 비하여 최고 582.2%까지 증가하였으며, 전류밀도는 최고 277.8% 증가하였다. 또한 전류밀도와 구리 석출량의 증가를 확산충의 두께 감소에 의한 증가효과와 표면세정과 유효충돌빈도의 증가에 의한 효과로 나누어 해석한 결과 초음파에 의한 확산충의 두께 감소로 인한 총괄 반응속도 증가율은 과전압이 2.2V, 황산구리의 농도가 0.1M일 때 최고 277.8%로 나타났으며, 표면세정과 유효 충돌빈도의 증가로 인한 총괄 반응속도 증가율은 과전압이 2.1V, 황산구리의 농도가 0.1M일 때 최고 253.6%로 나타났다. In this study, the ultrasound which provides the properties of mixing, and surface cleaning effect, the increase of the effective reaction surface area and the enhancement of the effective collision frequency, was used to enhance the recovering efficiency of Cu from the Cu-ion containning waste water. The ultrasonic reactor used in this study was designed and constructed for improving the disadvantage of the existing ultrasonic reactor. From the experimental result and its analysis, we obtained following conclusions. 1. The ultrasound increased the rate of electrochemical deposition to 582.2% in maximum at the condition of 0.1M-CuSO_4 and 2.1 V-overpotential. 2. The enhancement effect of ultrasound induced by the reduction of diffusion layer thickness was 277.8% in maximum and induced by the other effect except for the reduction effect of the diffusion layer thickness was 253.6% in maximum at 0.1M-CuSO_4 and 2.1V overpotential. 3. This study gave the possibility of the scale-up of ultrasonic reactor and in particular, ultrasonic reactor would be effective in the treatment of waste water containing a low concentration of Cu ion.
전기분해에 의해 제조된 NaOCl을 이용한 염색폐수의 처리 특성(II)
윤용수,하범용,Yoon, Yong-Soo,Ha, Beom-Yong 한국섬유공학회 2006 한국섬유공학회지 Vol.43 No.4
This study was performed to determine the feasibility of electrolytically produced NaOCl solution for the treatment of dyeing wastewater discharged from textile industry. Industrial dyeing wastewater was pre-treated by PAC coagulant and the optimal pH and dosage for coagulation were 6.5 and 0.05 v/v%, respectively In this pre-treatment process $COD_{Mn}$, color and suspended solids removal efficiency were 66%, 91% and 85%, respectively. After pre-treatment by coagulation, NaOCl solution made by electrolysis was used for the treatment of industrial wastewater. The optimal mixing ratio with NaOCl solution and dyeing wastewater was determined to be 1:5 at pH 5.0 and in these conditions, color and removal efficiency were 99% and 88%, respectively. From these results, we can expect that NaOCl solution produced by electrolysis with salt of a lower price can be used for the treatment of industrial dyeing wastewater conveniently and effectively, and can overcome disadvantage of a commercial NaOCl solution with a bad storage and delivery properties to decreas oxidation ability.
초음파를 이용한 하수 슬러지 분해에서 유기물 방출과 질소 거동
윤용수,강광남,최석순,Yoon, Yong-Soo,Kang, Gwang-Nam,Choi, Suk-Soon 유기성자원학회 2002 유기물자원화 Vol.10 No.4
The sewage sludge with concentrated MLSS, ranging from 5967 to 8400mg/L was degraded by ultrasound. In this study, ultrasound treatment was used to investigate the behavior characterization of SBOD, sludge biodegradation, C/N ratio, TN, turbidity and sludge morphology. From the experimental results of C/N ratio change and TN removal, the optimal irradiation time was found to be 10 minutes. The results showed the relative index of sludge biodegradation(SBOD/TCOD) was enhanced to 0.76 from the initial value of 0.013 at the 5967mg/L MLSS, during the 60minutes treatment. Throughout this research, the results provide useful engineering reference data for reuse of sewage sludge using ultrasound. MLSS 농도가 5967에서 8400mg/L인 농축 하수슬러지가 초음파에 의하여 분해되었다. 본 연구에서는 초음파를 이용한 하수슬러지의 처리시 용해성 BOD, 슬러지 생분해성, C/N 비, 총질소, 탁도, 슬러지 형태학적인 변화에 대한 거동 특성을 조사하였다. C/N비와 총질소 제거 실험에서 최적의 초음파 조사시간이 10분임을 알 수 있었다. 그리고 조사시간 60분 경과한 MLSS 5967mg/L의 슬러지 생분해도(SBOD/TCOD)는 초기값 0.013에서0.76으로 증가되었다. 따라서 본 연구를 통하여 얻어진 실험 결과들은 초음파를 이용한 하수슬러지 재활용에서 유용한 공학적 참고자료로 활용될 수 있을 것이다.
윤용수 ( Yong Soo Yoon ),배철호 ( Chul Ho Bae ),최석순 ( Suk Soon Choi ) 한국공업화학회 2002 공업화학 Vol.13 No.7
본 연구에서는 오존과 초음파를 이용하여 도시하수 처리장에서 발생하는 슬러지를 처리하고, 처리 전ㆍ후의 슬러지 특성을 비교ㆍ검토함으로써 오존과 초음파의 이용 가능성에 대하여 확인하였다. 초기 MLSS농도가 7233 mg/L인 슬러지 중에 존재하는 용해성 유기물의 용출속도상수(k)는 초음파 처리 경우에 0.297 min^-1, 오존처리 경우에 0.102 min^-1로 나타났다. 슬러지의 파괴에 의해 용출되는 유기물의 양을 확인하기 위하여 SCOD, SBOD를 분석하였으며, 영양염류인 총질소와 총인의 용출에 대하여 고찰하였다. 초음파처리에 의해 MLSS 1 g당 SCOD와 SBOD는 각각 0.127g, 0.181g이 용출되었으며, T-N과 T-P는 각각 0.038 g, 0.039 g이 용출되었다. 또한 오존처리시에는 SCOD와 SBOD는 각각 0.038 g, 0.058 g이 용출되었으며, T-N과 T-P는 각각 0.011 g, 0.012 g이 용출되었다. 그리고 슬러지의 생분해 가능성의 상대적인 척도가 되는 SBOD/TCOD비는 MLSS농도가 5733 mg/L인 슬러지의 경우 초기 0.024에서 초음파와 오존처리된 후에 각각 0.51과 0.21로 크게 증가되었다. In this study, ozone and ultrasound were adopted for the treatment of waste sludge from the municipal sewage treatment plant, and the properties of the treated sludge and that of the raw sludge were compared. For the waste sludge with MLSS concentration of 7233 mg/L, the degradation rate constants of dissolved organic matters were 0.297 min^-1 and 0.102 min^-1 for ultrasound treatment and ozone treatment, respectively. To evaluate the characteristics of the released organic matters and nutrient by sludge degradation in the ultrasound treatment, SCOD, SBOD, T-N and T-P were analyzed. It was found that 0.127 g of SCOD, 0.181 g of SBOD, 0.038 g of T-N and 0.039 g of T-P were released per g of MLSS, respectively. In the case of ozone treatment, the quality of released of SCOD, SBOD, T-N and T-P were 0.038 g, 0.058 g, 0.011 g and 0.012 g per g of MLSS, respectively. In addition, the SCOD/TCOD, relative index of sludge biodegradation was enhanced to 0.51 with ultrasound treatment and 0.21 with ozone treatment from initial value of 0.024 in waste sludge with MLSS concentration of 5733 mg/L.
윤용수 ( Yong Soo Yoon ),이재천 ( Jae Chon Lee ) 大韓遠隔探査學會 1999 大韓遠隔探査學會誌 Vol.15 No.3
원격탐사 관련 핵심기술은 최근에 국방, 의료영상, 환경, 지질 등과 같은 광범위한 분야에서 활용범위를 확대하고 있다. 1 cm~수십 cm 파장의 파를 관측하는 마이크로파 원격탐사 기술은 반사 적위선 원격탐사나 열 적외선 원격탐사 기술에 비해 날씨조건과 밤낮에 관계없이 탐사를 수행할 수 있다는 장점을 가지고 있다. 마이크로파 영상레이다인 합성 개구 레이다를 이용한 영상화 방식은 응용목적에 따라 stripmap 방식, spotlight 방식, 그리고 inverse 방식으로 구분된다. 본 논문에서는 inverse 방식으로 지상에 고정된 레이다가 비행하는 항공체를 영상화하는 기법에 대해서 기술하였다. 비행 항공체의 영상화 기법은 자동 표적인식 시스템 구축시 중요한 기술단계이며, 최근 이 분야에 대해 활발히 연구되고 있다. 비행 항공체를 영상화하기 위해 제안된 3가지 방식인 퓨리에 처리 기법, 시간-주파수 처리 기법, 그리고 투시로부터 복원 기법을 소개한 후, 각 방식의 장단점을 분석하였다. So far, the remote sensing technology has widely been used in a variety of application areas such as military, medical imaging, environment, geology and so forth. The microwave remote sensing uses the wavelengths ranging from around one centimeter up to a few tens of centimeters and is known to be very effective regardless of the weather conditions and the day/night time as compared with the reflective InfraRed (IR) remote sensing or the thermal IR remote sensing. There are three generic modes of synthetic aperture radar imaging systems depending on its application, that is, stripmap mode, spotlight mode, or inverse mode. In this article we focus on the issue of imaging of flying aircrafts for the inverse mode of a ground-based, fixed radar with moving objects. The imaging of flying aircrafts is considered to be an important step for the automatic target recognition systems, and therefore a great deal of efforts have recently been made on the subject. Here we review the three representative methods including the Fourier transform processing, the time-frequency processing, and the reconstruction from the projection. Some relative merits and drawbacks are also discussed.