        박스형 공동주택 거실에서 중량바닥충격음 수음점 위치에 대한 적정성 연구

        오양기,주문기 한국건축친환경설비학회 2019 한국건축친환경설비학회 논문집 Vol.13 No.6

        In this paper, the validity of the receiving points in the heavy weight floor impact sound was investigated by measuring a room mode. Living rooms of different sizes were analyzed by grid measurement. As a result, the sound pressure level was the lowest in the 80 Hz band, which is the one half of the receiving room. It was shown that the fixed microphone position was likely to cause different result by the room mode. The result was the same according to the size of the receiving room. As shown in ISO 16283-2, it was expected that the 4 points of the receiving room would be avoided center points, corners, and nearby walls. Also, the point at which receiving point on the same plane is symmetrical was shown to be avoided. Through this measurements, the minimum guidelines for the receiving points were proposed when measuring the heavy weight impact sound.

      • KCI등재
      • KCI우수등재

        방음터널 단면형상에 따른 소음저감 예측 및 특성 평가 : 터널 외부소음을 중심으로

        오양기,김하근,이원열 대한건축학회 2004 대한건축학회논문집 Vol.20 No.8

        Noise emitted from urban arterial roads is getting more serious problem in the environmental quality of living. Though noise barrier is one of measures to mitigate noise levels at housing area, it has a limited effect especially on apartment units high around the roads. Noise barrier tunnel may be another effective device for noise reduction even to high rise apartments. On these basis, this study aims at providing a number of possible sectional shapes of noise barrier tunnels, measuring their effects on noise reduction with 1 to 5 scale model measurements, and proposing/validating a prediction technique of their effects. According to a number of measurements with various sectional shapes or the scaled model, 1)the proposed sectional shapes have affirmative effects on noise reduction, 2)the difference in noise levels between in and out of tunnel are about 10dB whether there is opening in the ceiling or not. 3)results from predictions and the measurements show generally good agreements within 0.3∼3.6 dB(A).

      • KCI등재

        마이크로폰의 위치에 따른 중량 바닥충격음레벨의 편차

        오양기,주문기,박종영,김하근,양관섭,Oh Yang-Ki,Joo Moon-Ki,Park Jong-Young,Kim Ha-Geun,Yang Kwan-Seop 한국음향학회 2006 韓國音響學會誌 Vol.25 No.2

        현행 중량 바닥충격음 표준 측정방식인 KS F 2810-2에 의하면 중앙점을 포함한 3-5곳의 타격위치에 대하여 수음실에서 4곳 이상의 지점의 피크레벨을 측정하도록 되어있다. 그러나 이 표준 방식에 의한 동일 상황에서의 측정 결과가 측정기관, 측정횟수, 측정점의 위치 등에 따라 일관성을 보이지 못하고 있음이 종종 발견된다. 이러한 편차는 반복성이나 재현성의 측면에서 측정값의 신뢰도에 영향을 미칠 수 있는 수준으로 우려된다. 측정결과 실험실의 경우 중앙 타격시 63Hz 대역에서 각 지점간의 차이가 l0dB이상 차이를 보였으며, 전체적으로 중간주파수 대역에서 보다 저주파수 대역에서의 편차가 크게 발생하는 것으로 나타났다. 이러한 편차는 저주파수 대역에서의 모드 중첩현상에 의한 것으로 보인다. 현행 바닥충격음 단일지수 평가 방법에 따라 평가한 결과 측정위치에 따라 단일지수 평가값에 2-7dB의 차이를 보였으며 바닥충격음 차음성능 평가에 영향을 줄 수 있을 것으로 판단되었다. 따라서 향후 저주파 대역의 편차를 줄이거나 저음의 모드 중첩에 의한 영향을 배제할 수 있는 측정 혹은 평가 방식의 개선이 필요하다고 사료된다. Measurement of impact sound insulation of floor, by current Korean Standard KS F 2810-2. is to be made with peak levels over 4 point in a receiving room. But it is often the case that there is inconsistency in results at various receiving points in the receiving room. Such variations obviously have effects on the repeatability and reproducibility of measured data. The result shows that there are even 10 dB deviations in 63Hz octave band frequency range and relatively less variations are occurred in other low frequency ranges. Such variations seems to be coming from modal overlaps of the receiving room. According to current rating method of floor impact sound. KS F 2863-2, that may affect on the single number latins scheme. From the result of tests in this study, there are 2dB to 6dB differences in the sin91e number with the combination of measurement points. This means that the reduction of measurement variations from the microphone positions is needed for a better credibility of measurement results.

      • KCI등재
      • 大形講議室의 建築設計에 관한 硏究 : 光州大學校 大形講議室의 音響改修를 中心으로

        吳洋基,金承眞 광주대학교 1990 論文集 Vol.7 No.-

        This study deals with the architectural and acoustical requirements of large lecture rooms, In practice, there are many cases in building such roomss without any acoustic considerations, In the study, the practical method which ensure a better acoustic quality for the rooms of poor speech communication quality is introduced. The method is consist of some modifications which is concerned the total absorption capability and the background noise level, in precise, the signal-to-noise ratio. The modification performed in the large lecture room of Kwangju University shows that the method is very useful to acquire better acoustic condition.

      • 건축물 음환경 평가 프로그램

        오양기,정대업,이희원 대한설비공학회 2002 설비저널 Vol.31 No.4

        건축물의 실내 음향계획 및 평가를 위해 활용되고 있는 건축음향 프로그램에 대해서 소개를 하고자 한다.

      • KCI등재

        방음판의 흡음률 측정방법 제안을 위한 기초 연구

        오양기,김하근 한국음향학회 2023 韓國音響學會誌 Vol.42 No.2

        Sound barrier walls are the most basic way to cope with noise problems in urban residential environments. The most important acoustic function of sound insulation board is represented by sound transmission loss and sound absorption coefficient. However, Korea has not yet established a standard for measuring the sound absorption rate of sound insulation boards. In addition, even in the European standard, where the overall acoustic standard of soundproofing boards has already been established, the sound absorption rate is applied only to the standard for measuring the sound absorption rate of general building finishing materials, and a separate measurement method considering the characteristics of soundproof walls and soundproofing boards is not presented. The sound absorption coefficient should be evaluated by summing up the energy absorbed into the material as well as the energy transmitted through the material, but the current European standard has a problem in that the transmitted sound energy is not taken into account. In this paper, we reviewed the sound absorption coefficient measurement standards of sound insulation boards currently being presented, and verified the difference between the results and the new measurement method considering transmission sound for sound insulation boards actually used in Korea. 방음벽은 도시 주거환경의 소음문제에 대응하기 위한 가장 기본적인 방법이다. 방음판의 가장 중요한 음향적기능은 음향투과손실과 흡음률로 표시된다. 특히 주거시설이 밀집되어있는 도심구간의 철도나 간선도로에서 원하지않는 반사음에 의한 2차 소음 문제를 최소화하기 위하여는 방음판의 흡음성능이 중요하다. 그러나 아직까지 우리나라는 방음판의 흡음률 측정방법에 관한 규격이 마련되어있지 않다. 또한 방음판의 전반적인 음향규격이 이미 만들어져있는 유럽규격에서조차 흡음률에 관해서는 일반적인 건축마감재료의 흡음률 측정기준을 준용하고 있을 뿐, 방음벽과방음판의 특성을 감안한 별도의 측정방법을 제시하지 못하고 있다. 흡음률은 재료의 내부로 흡수된 에너지 뿐 아니라재료를 투과한 에너지까지 합산하여 평가되어야 하는데 현재의 유럽규격은 투과음 에너지를 감안하지 못하고 있는문제를 안고 있다. 이 논문에서는 현재 제시되고 있는 방음판의 흡음률 측정 규격에 대해 고찰하고, 우리나라에서 실제 사용되고 있는 방음판을 대상으로 투과음을 감안한 새로운 측정방법과의 결과 차이를 검증하였다. 아울러 새로운 방음판 흡음률 측정규격의 마련을 위한 기초적 아이디어를 제시하였다.