http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
ECG신호의 피치변동해석 및 Hilbert변환에 의한 후두기능의 평가
송철규,이명호 대한의용생체공학회 1995 의공학회지 Vol.16 No.1
In this study, we have evaluated the effect of amplitude and frequency perturbation of EGG signal for single vowels associated with laryngeal pathology. The normal EGG signal was properly characterized by an autoregressive model which has an optimal order of ninth using the parametric method. This can be analyzed by determining the transfer function. Perturbations in the fundamental pitch and in the peak amplitude of EGG signal measured with a four-electrode system using the modulation/demodulation techniques were investigated for the purpose of developing a decision criteria for the laryngeal function analysis. The abnormal EGG signal has nonperiodic and unstable characteristics. It can be discriminated by the calculation of opening and closing time of glottis using the EGG signal. In case of normal and abnormal subjects, m$\pm$0.5*sd was discriminating line for frequency perturbation and m$\pm$2*sd for normal amplitude perturbations, respectively. Also, The normal and abnormal cases of the subjects can be discriminated effectively using the pattern of attractor derived with Hilbert transform of EGG signal. 본 논문에서는 발성기관인 후두(glottis)의 기능을 평가하기 위하여 후두신호의 주파수 변동과 진폭변동의 영향을 분석하였다. 정상인의 EGG(electroglottograph)신호는 매개변수 방법을 이용하여 최적의 차수가 9차인 자귀회귀형 모델로 설명할 수 있으며, 이것은 전달함수를 결정함으로써 해석이 가능하다. EGG신호의 진푹과 주파수의 변동은 변복조방식의 4전극 EGG 시스템으로 얻어지며, 후두기능 상태식별을 목적으로 개발하였다. EGG를 이용하여 후두의 닫힘구간과 열림구간을 계산함으로써 비정상 EGG신호는 비주기적이며 불안정한 상태라는 것을 구별할 수 있었다. 정상과 비정상의 피검자들을 구분할 수 있는 파라미터인 주파수 변동은 정상인의 m$\pm$0.5*sd이고, 진폭변동은 m$\pm$2*sd가 각각 되었다. 또한 EGG신호를 Hillbert 변환함으로써 얻어진 궤적의 패턴을 이용하여 정상과 비정상의 후두기능상태를 효과적으로 분류할 수 있었다.
3차원 내시경술을 위한 양안 입체 영상처리 및 디스플레이 방법
송철규 대한의용생체공학회 1998 의공학회지 Vol.19 No.5
본 논문은 내시경 수술시 입체영상을 제공하여 수술의 편리성과 정확성을 향상시키기 위한 고화질 3차원 내시경 영상의 처리와 디스플레이 방법을 연구하였다. 기존의 3타원 내시경 수술을 위한 디스플레이 방법은 안경 차용의 무게감과 플리커가 심한 전자셔터 방식으로 사용의 불편함이 많았다 된 연구에서는 기존 내시경 영상의 3D 디스플레이 방식인 전자셔터식에 대한 입체 영상의 특징을 분석하고, 이에 대한 문제점을 보완하기 위한 편광방식의 입체 영상처리와 재현 방법에 대하여 연구하였다. 또한 설계한 디스플레이 시스템의 성능 평가를 수행하여 기존 방식인 CRT방식에 의한 영상재현 방법에 비해 화질과 시야각 특성에서 우수함을 확인하였다. This paper represents the design of 3D endoscopic image processing system in order to Improve visualization and enhance the ability of the surgeon to perform delicate endoscopic surgery. The proposed 3D systems have four features of stereo endoscopic image processing The multiplexer give field seauential stereo for recording and for aligning cameras and viewing stereo with 3D monitor. Demultiplexing of the field sequential image which separates out the R and L images for dual TFT-LCD 3D monitor viewed with passive polarized glasses. separable processing of the left and right eye images, and design of TFT-LCD 3D monitor. The viewing angle, zone, and image quality of the Polarization-type Stereoscopic Display (SM500TFT-3D) system which we have developed using 15 Samsung TFT-1.CD with a screen resolution of 1024×768 pixels were measured and compared with those of Electric Shutter-type Stereoscopic Display system. The result of experiments shows that the Polarization-type Stereoscopic Display System using TFT-LCD has a wade viewing angle and zone which Is necessary fort multi-view and it has better image quality and stability of the optical performances than the Electric Shutter-type does.
생체 임피던스를 이용한 인체 하지운동 출을 위한 최적 전극위치 선정
송철규,윤대영,이동헌,김수찬,김덕원 대한전기학회 2003 전기학회논문지 D Vol.52 No.8
- This paper describes the possibility of analyzing gait pattern from the changes of the lower leg electrical impedance. This impedance was measured by the four-electrode method. Two current electrodes were applied to the thigh, knee, and foot., and two potential electrodes were applied to the lateral, medial, and posterior position of human leg. The correlation coefficients of the joint angle and the impedance change from human leg movement was obtained using a electrogoniometer and 4ch impedance measurement system developed in this study. We found the optimal electrode position for knee and ankle joint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. The correlation coefficients of the ankle, knee, and the hip movements were -0.913, 0.984 and 0.823, respectively. From such features of the human leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level. This system showed feasibility that lower leg movement could be easily measured by impedance measurement system with a few skin-electrodes.
Evaluation of Clinical Effectiveness of 3D Digital Endoscopic Image
송철규,김경섭,김남균,Song, Chul-Gyu,Kim, Kyeong-Seop,Kim, Nam-Gyun The Korean Society for Digital Imaging in Medicine 2002 대한디지털의료영상학회논문지 Vol.5 No.1
본 연구의 목적은 복강경 수술환경에서 2D와 3D 내시경 비디오 영상이 수술에 미치는 영향을 평가하기 위한 연구이며, 이를 위해 3D 내시경 시스템을 구성하고 성능 평가를 수행하였다. 결과적으로 본 연구에서 제안한 3D 방식이 기존의 전자셔터 방식에 의한 3D 영상에 비해 화질과 시야각이 우수하며, 2종류의 모의 수술 실험 비교를 한 결과, 제안한 방식의 디지털 영상을 이용하는 경우가 성능이 가장 우수함을 정량적으로 확인하였다. This paper represents the design of 3D endoscopic video system in order to improve visualization and enhance the ability of the surgeon to perform delicate endoscopic surgery. Minimally invasive techniques have set new standards in all surgical may experience less post-operative discomfort, shorter hospitalization, and quicker recuperation. Finally, the aim of the present study was to determine the influence of 2D and 3D video imaging on defined tasks on a laparoscopic trainer.