RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        다양한 산소분압에 따른 용융 Ag-Sn 및 Ag-Cu 합금의 표면장력

        민순기,이준호,Min, Soon-Ki,Lee, Joon-Ho 한국재료학회 2009 한국재료학회지 Vol.19 No.1

        A semi-empirical method to estimate the surface tension of molten alloys at different oxygen partial pressures is suggested in this study. The surface tension of molten Ag-Sn and Ag-Cu alloys were calculated using the Butler equation with the surface tension value of pure substance at a given oxygen partial pressure. The oxygen partial pressure ranges were $2.86{\times}10^{-12}$-$1.24{\times}10^{-9}$ Pa for the Ag-Sn system and $2.27{\times}10^{-11}$-$5.68{\times}10^{-4}$ Pa for the Ag-Cu system. In this calculation, the interactions of the adsorbed oxygen with other metallic constituents were ignored. The calculated results of the Ag-Sn alloys were in reasonable accordance with the experimental data within a difference of 8%. For the Ag-Cu alloy system at a higher oxygen partial pressure, the surface tension initially decreased but showed a minimum at $X_{Ag}$ = 0.05 to increase as the silver content increased. This behavior appears to be related to the oxygen adsorption and the corresponding surface segregation of the constituent with a lower surface tension. Nevertheless, the calculated results of the Ag-Cu alloys with the present model were in good agreement with the experimental data within a difference of 10%.

      • IMT - 2000 / CDMA 시스템의 효율적인 링크 분석을 위한 프로그램 개발

        민순기(Soon-Ki Min),김완태(Wan-Tae Kim),김명준(Myung-Joon Kim) 한국정보과학회 2001 한국정보과학회 학술발표논문집 Vol.28 No.2Ⅲ

        최근 이동 통신의 급격한 성장으로 인하여 동일한 통신 서비스간의 간섭 뿐 아니라 서로 다른 서비스간의 간섭 문제가 통신 서비스의 품질을 저하시키는 주된 요인으로 작용하고 있다. 특히, CDMA-based 시스템은 간섭에 의해 용량이 제한되므로 CDMA-based 시스템인 기존의 IS-95 및 PCS 서비스, 그리고 차세대 이동 통신인 IMT-2000/CDMA 시스템의 용량 개선을 위한 연구 및 효율적인 무선망 설계를 위한 연구가 필요하다. 본 연구에서는 IMT-2000/CDMA 시스템의 효율적인 링크 분석(Link Analysis)을 하는데 필요한 시스템 성능 평가와 시스템 통화용량을 산출하는 프로그램을 개발하고자 한다. 여기서, 시스템 성능을 예측하기 위해서는 신호 대 잡음 전력비 (E_b/N_o)의 개념이 요구된다. 시스템 통화용량은 잡음 특성이 매우 이상적인 상태를 기준으로 하여 역방향 최대 용량을 산정하는 Pole Capacity 산출 방식과 호차단율(Blocking Probability)로부터의 통계적 산출 방법인 Erlang Capacity 산출 방식을 적용한다.

      • KCI등재

        양성자빔-나노라디에타 혈전용해를 위한 마우스 혈전모델에서 산화철나노입자의 선택적 축적에 관한 연구

        김종기,민순기,전재근,한성미,김홍태,김기홍 한국물리학회 2014 새물리 Vol.64 No.3

        Proton-impact high-Z metallic nanoparticles produce burst emissions of low-energy electrons, including interatomic Coulomb decay electrons and Auger electrons (0-1000 eV), termed as the Coulomb nanoradiator (CNR) effect, thus damaging and having a therapeutic effect on the pathological tissues impacted by the nanoparticles. This pilot study attempts to investigate the macrophage-mediated uptake of iron-oxide nanoparticles (Fe₃O₄, FeO-NP) in the thrombus for potent CNR-based thrombolysis. In a ferric-chloride mouse arterial thrombus model, FeO-NP were intravenously injected, and the thrombus uptake of the iron NP was evaluated in the temporally-extracted vessels with Perl's Prussian blue staining. The NP distribution in the thrombus dependened on the post-injection circulation time, and no iron uptake was observed at either 30 minutes or 2 hours after injection. In contrast, homogeneous uptake of iron NP was observed in the central thrombus at 22 hours post-injection while no uptake was observed in the normal intima or adventia. These results suggest potent noninvasive CNR thrombolysis when using a high-energy traverse Bragg-peak proton or ion beam. proton-impact high-Z 금속나노입자는 원자간쿨롱붕괴-전자, Auger전자 등 다발성 저에너지전자방출의 (0-1000 eV) 쿨롱나노라디에타효과 (Coulomb nanoradiator effect; CNR)를 생성, 나노입자가 축적된 병소조직을 손상-치료효과를 유발한다. 본 pilot 연구는 혈전내 대식세포-중개 금속나노입자의 축적여부에 따른 CNR-혈전용해치료 가능성을 타진하기 위해, ferric-chloride 마우스 경동맥 혈전모델에서, Iron oxide 나노입자 (Fe₃O₄)를 정맥주사하고, 혈전내 나노입자의 축적 여부를 circulation time 함수로 적출된 혈관에서 Perl's Prussian blue 염색법으로 관찰하였다. 주사 후 경과시간에 따라 혈전내 축적양상은 달랐으며, 30분, 2시간 뒤에는 혈전내 축적이 관찰되지 않았으나 22시간 뒤, 혈관의 내막이나 adventia등에서는 나노입자의 축적이 일어나지 않는데 반해 혈전중심부위에서 철나노입자의 축적을 최초로 확인하였다. 동 결과는 Traversing Bragg-peak 양성자 또는 중이온 빔을 이용 쿨롱나노라디에타 효과에 의한 새로운 비침습적 혈전용해법 가능성을 제시하고자 한다.

      • 체내 배액관 파열 현상의 원인분석과 관리 문제점 연구

        박성우,이우백,민순기,강영한,윤현곤,전상훈,이창현 대한인터벤션영상기술학회 2017 대한인터벤션영상기술학회지 Vol.20 No.1

        We investigated the cause of frequent pigtail catheter rupture in vivo. Experiments focus on the burst of catheters due to external pressure. The Dowson-Mueller Drainage Catheter 8.5 Fr from Cook Medical was used as an experimental tool. First, the tip of the pigtail catheter was completely closed and the pressure was applied using an in-deflator. As a result, ballooning and bursting occurred at average 17.2±1.03 atm in 22℃. and occurred at average 13.0±0.47 atm in 37℃ distilled water. This was the same shape that occurred in the patient’s. Based on these results and by conducting additional surveys, 27% of the managers were unaware of the risk of burst. Therefore, if specific guidelines and education are given to patients and administrators, the burst of the catheter will be prevented.

      • 세기변조방사선치료에서 Pitch와 Roll 변화에 따른 선량전달 정확성 평가

        정창영,배선명,이동형,민순기,강태영,백금문,Jeong, Chang Young,Bae, Sun Myung,Lee, Dong Hyung,Min, Soon Ki,Kang, Tae Young,Baek, Geum Mun 대한방사선치료학회 2014 대한방사선치료학회지 Vol.26 No.2

        목 적 : 세기변조방사선치료에서(Intensity modulated radiation therapy,IMRT) 6D robotic couch의 pitch 와 roll 변화에 따른 선량전달의 정확성을 평가하고자 한다. 대상 및 방법 : Trilogy(Varian Medical Systems, USA)와 6D robotic couch(ProturaTM 1.4, CIVCO, USA)를 사용하여 골반부위의 세기변조방사선치료를 진행한 14명의 환자를 대상으로 영상유도 시 발생한 pitch 와 roll 방향의 오차 값과 발생빈도를 분석하였다. 오차의 변화에 따른 선량전달 정확성의 차이를 평가하기 위해 pitch 와 roll의 변화가 $0^{\circ}$인 상태의 측정치를 기준으로 각각 $1.0^{\circ}$, $1.5^{\circ}$, $2.0^{\circ}$, $2.5^{\circ}$로 변화시킨 경우에 대하여 2차원 이온전리함 배열 검출기(I'mRT Matrixx, IBA Dosimetry,Germany)와 MultiCube Phantom(IBA Dosimetry, Germany)를 이용하여 측정 후 감마지수(3 mm, 3%)의 비교평가를 실시하였다. 실험에는 Dynamic Multi-Leaf Collimator의 sliding window기법을 사용한 3명의 자궁경부암 치료계획을 적용하였다. 결 과 : 대상 환자의 영상(3D/3D Match 78건, 2D/2D match 79건)을 분석한 결과 pitch 와 roll의 평균 오차값은 $0.9^{\circ}{\pm}0.7$, $0.5^{\circ}{\pm}0.6$, 최대 값은 $2.8^{\circ}$, $2.0^{\circ}$로 분석되었고, 최소값은 pitch 와 roll 모두 $0^{\circ}$으로 나타났다. 각각의 조건에서 측정된 선량전달에 대하여 감마지수를 이용하여 비교한 결과, pitch가 $1.0^{\circ}$, $1.5^{\circ}$, $2.0^{\circ}$, $2.5^{\circ}$일 때 gamma pass rate의 평균은 각각 97.75%, 96.65%, 94.38%, 90.91%, roll의 경우 $1.0^{\circ}$, $1.5^{\circ}$, $2.0^{\circ}$, $2.5^{\circ}$에서 평균 93.68%, 93.05%, 87.77%, 84.96%로 나타났고, pitch 와 roll을 동시에 변화시킨 경우 $1.0^{\circ}$, $1.5^{\circ}$, $2.0^{\circ}$에서 평균 94.90%, 92.37%, 87.88%의 결과 값을 얻었다. 결 론 : 대상 환자의 영상 유도 시 pitch 와 roll의 오차 발생률은 전체 치료 횟수에서 각각 82.20%, 72.20%로 분석되었고, 감마지수를 통해 오차 값이 커질수록 선량전달의 정확성이 낮아진다는 것을 확인할 수 있었다. 세기변조방사선치료 시 선량전달의 정확성을 높이기 위해서는 정확한 자세잡이와 더블어 적절한 영상유도를 통해서 pitch 와 roll 방향으로 발생할 수 있는 오차를 줄이도록 노력해야 할 것으로 사료된다. Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the pitch and roll rotational setup error with 6D robotic couch in Intensity Modulated Radiation Therapy (IMRT) for pelvic region in patients. Materials and Methods : Trilogy(Varian, USA) and 6D robotic couch(ProturaTM 1.4, CIVCO, USA) were used to measure and analyze the rotational setup error of 14 patients (157 setup cases) for pelvic region. The total 157 Images(CBCT 78, Radiography 79) were used to calculate the mean value and the incidence of pitch and roll rotational setup error with Microsoft Office Excel 2007. The measured data (3 mm, 3%) at the reference angle ($0^{\circ}$) without couch rotation of pitch and roll direction was compared to the others at different pitch and roll angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) to verify the accuracy of dose delivery by using 2D array ionization chamber (I'mRT Matrixx, IBA Dosimetry, Germany) and MultiCube Phantom(IBA Dosimetry, Germany). Result from the data, gamma index was evaluated. Results : The mean values of pitch and roll rotational setup error were $0.9^{\circ}{\pm}0.7$, $0.5^{\circ}{\pm}0.6$. The maximum values of them were $2.8^{\circ}$, $2.0^{\circ}$. All of the minimum values were zero. The mean values of gamma pass rate at four different pitch angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) were 97.75%, 96.65%, 94.38% and 90.91%. The mean values of gamma pass rate at four different roll angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) were 93.68%, 93.05%, 87.77% and 84.96%. when the same angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$) of pitch and roll were applied simultaneously, The mean values of each angle were 94.90%, 92.37% and 87.88%, respectively. Conclusion : As a result of this study, it was able to recognize that the accuracy of dose delivered is lowered gradually as pitch and roll increases. In order to increase the accuracy of delivered dose, therefore, it is recommended to perform IGRT or correct patient's position in the pitch and roll direction, to improve the quality of treatment.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼