        온실의 기간난방부하 산정을 위한 난방적산온도 비교분석

        남상운,신현호,서동욱 (사) 한국생물환경조절학회 2014 생물환경조절학회지 Vol.23 No.3

        To establish the design criteria for seasonal heating load calculation in greenhouses, standard weather dataare required. However, they are being provided only at seven regions in Korea. So, instead of using standard weatherdata, in order to find the method to build design weather data for seasonal heating load calculation, heating degreehourand heating degree-day were analyzed and compared by methods of fundamental equation, Mihara’s equationand modified Mihara’s equation using normal and thirty years from 1981 to 2010 hourly weather data provided byKMA and standard weather data provided by KSES. Average heating degree-hours calculated by fundamental equationusing thirty years hourly weather data showed a good agreement with them using standard weather data. The 24times of heating degree-day showed relatively big differences with heating degree-hour at the low setting temperature. Therefore, the heating degree-hour was considered more appropriate method to estimate the seasonal heatingload. And to conclude, in regions which are not available standard weather data, we suggest that design weather datashould be analyzed using thirty years hourly weather data. Average of heating degree-hours derived from every yearhourly weather data during the whole period can be established as environmental design standards, and also minimumand maximum of them can be used as reference data for energy estimation. 우리나라 각 지역별 온실의 기간난방부하 산정용 난방적산온도 자료를 구축하기 위해서는 표준기상데이터가필요하다. 그러나 국내에는 서울과 6대 광역시 등 7개지역만 표준기상데이터가 제공되고 있어서 이를 대체할수 있는 방법을 찾아야 한다. 전국적으로 이용이 가능한기상자료는 기상청의 일별 평년값 자료 및 30년(1981~2010)간 매 시각 전체 기상자료이므로 이를 이용하여 난방디그리아워와 난방디그리데이를 구하였다. 표준기상데이터가 있는 7개 지역을 대상으로 평년값 자료및 전체 기상자료를 사용하여 구한 난방디그리데이와 난방디그리아워를 표준기상데이터를 사용하여 구한 결과와비교하였다. 전체 기상자료를 이용하여 기본식으로 구한난방디그리아워의 평균값이 표준기상데이터로 구한 것과잘 일치하는 것으로 나타났다. 또한 평년값을 이용하여수정 Mihara식으로 구한 난방디그리아워도 표준기상데이터로 구한 것과 거의 비슷한 경향을 보였다. 이에 비하여 평년값을 이용하여 Mihara식으로 구한 난방디그리아워는 표준기상데이터로 구한 것 보다 훨씬 작았고 전체 기상자료의 최소값에 가까운 것으로 나타났다. 난방디그리아워와 동일한 단위로 환산했을 때, 난방 설정온도가 높을 경우에는 난방디그리데이와 난방디그리아워의차이가 별로 없었으나, 설정온도가 낮을 경우에는 난방디그리데이 방식이 난방디그리아워 방식보다 지역에 따라3~26%나 작게 나타나는 것으로 분석되었다. 난방디그리데이는 평년값을 이용하여 기본식으로 구할 수 있기 때문에간편한 방법이지만 설정온도가 낮을 경우 오차가 크게 발생되므로 난방디그리아워 방식이 더 합리적인 방법으로판단된다. 결론적으로 온실의 환경설계용 기상자료 구축에서 난방적산온도는 평년값과 동일한 30년간의 시간별 기상자료를 이용하여 매년 난방디그리아워를 구하고 전체자료기간의 평균값을 설계 자료로 활용할 것을 제안한다. 또한 최대 및 최소 난방디그리아워 자료를 제공함으로써기상상황에 따른 에너지 소비량 예측 및 경제성 평가에활용할 수 있도록 할 필요가 있을 것으로 판단된다.

      • KCI우수등재

        친환경 농촌마을계획을 위한 재생에너지 활용방안 연구 - 태양에너지 자원분석 -

        남상운,김대식,Nam, Sang-Woon,Kim, Dae-Sik 한국농공학회 2008 한국농공학회논문집 Vol.50 No.3

        Solar energy, which is one of renewable energy, would be the most useful resources that can be applied to making energy recycling villages without using fossil energy. This study analyzed energy potential on solar energy considering weather condition in three traditional villages and compared with energy consumption surveyed. A photovoltaic system having 3.0kWp capacity of unit module can generate 182.5%, 96.1% and 170.9% of the yearly mean consumption of electric power in Makhyun, Boojang, and Soso, respectively. A flat-plate solar collector having $2.64m^2$ area of unit module can generate warm water of $142{\ell}$/day, $89{\ell}$/day, and $173{\ell}$/day, respectively in three study villages. In Makhyun and Soso, photovoltaic power and warm water produced by solar energy were sufficient to supply required amount of electric power and warm water. However, both electric power and warm water produced by unit solar module were not sufficient in Boojang area, and so it is required to increase the module area by more than 50%. According to the results of this study, the appropriate combination of energy resources can be applied to rural green-village planning if the characteristic of energy potential for each local area is considered.

      • KCI등재

        하절기 온실의 활용실태 및 몇 가지 고온극복 방법별 열환경 분석

        남상운 한국생물환경조절학회 2000 생물환경조절학회지 Vol.9 No.1

        온실의 경제적 고온극복 방안의 방향 설정을 위한 기초 자료를 얻기 위하여 비닐하우스 96농가, 유리온실 75농가를 대상으로 하절기 온실의 활용실태를 조사한 결과 유리온실 18.7%, 비닐하우스 24.0%, 전체 21.6%의 시설재배 농가가 휴경하고 있었으며, 나머지 경우도 매우 열악한 환경 하에서 재배가 이루어지고 있었고, 고온 극복을 위한 저비용 기술의 개발에 관한 요구가 매우 높았다. 냉방 및 보조냉방 처리별 온실의 열환경을 비교 측정한 결과 자연환기만으로는 74.8%, 지붕살수시 58.2%가 35$^{\circ}C$를 초과하여 작물재배가 곤란한 것으로 나타났다 환기와 차광을 병행할 경우에는 26.9%만 35$^{\circ}C$를 초과하는 것으로 나타나 약간만 개선하면 어느 정도의 고온극복은 가능할 것으로 판단되었다. 차광과 증발냉각의 일종인 에어쿨팬의 가동으로 자연환기 온실에 비하여 3.8~4.2$^{\circ}C$의 냉방효과를 보였으며, 온실내의 기온을 대부분 35$^{\circ}C$ 이내로 유지하는 것이 가능한 것으로 나타났다. 증발냉각시스템의 도입으로 고온극복이 가능하지만 확대보급을 위해서는 비용절감 및 체계화기술 개발이 과제로 남아 있다. 한편, 차광과 고효율의 환기로 어느 정도의 고온극복이 가능하므로 비교적 시설비 투자가 적은 온실에 대하여는 환기시스템 및 차광방법 개선 등의 연구를 통한 경제적인 고온극복 방안 설정이 필요할 것으로 판단되었다. This study was performed to find an efficient method to overcome extremely high temperature in greenhouses during summer season. The actual utilization of greenhouses during hot summer season showed that about 21.6% of the investigated greenhouse farms were in fallow state, and most of greenhouse farms were cultivated under the very inferior environment. Thermal environment of greenhouses according to the evaporative cooling method and several assistant cooling methods such as ventilation, shading screen, roof sprinkling were examined. As the each assistant cooling method was used, about 74.8%, 25.9%, and 58.2% of temperatures measured at intervals of ten minutes between ten and seventeen o'clock were above 35$^{\circ}C$. When shading screen and evaporative cooling system were operated, most greenhouse air temperatures were maintained below 35$^{\circ}C$, and showed a drop of 3.8~4.2$^{\circ}C$ as compared with naturally ventilated greenhouse.

      • KCI등재

        플라스틱 온실의 폭설피해 방지를 위한 가지주 장치 개발

        남상운 한국농공학회 2002 한국농공학회논문집 Vol.44 No.4

        우리나라 온실의 대부분을 차지하고 있는 파이프 골조의 아치형 플라스틱 온실은 폭설이나 강풍으로 인하여 많은 피해를 입고 있다. 특히 대부분 지역의 설계적설심이 단동 온실의 안전적설심을 초과하고 있으므로 폭설에 대한 보강이 필요하다. 그러나 기둥설치나 골조의 보강은 작업성 및 투광성을 떨어뜨릴 뿐만 아니라 건축비의 증가를 초래하므로 보강용 가지주를 준비해 두었다가 대설 주의보가 발령되면 설치함으로써 폭설로 인한 피해를 방지할 수 있을 것이다. 본 연구에서는 플라스틱 온실용 아연도 강관을 이용한 응급 보강용 가지주 장치를 개발하고 추가적인 적설하중 지지 능력을 검토하였다. 파이프 상단에 끼워 지붕의 중앙 도리에 걸쳐서 상부하중을 안전하게 가지주로 전달할 수 있는 지붕연결장치와 상부하중을 안전하게 지반에 전달할 수 있는 바닥지지판을 설계하여 제작하였다. 폭이 각각 5, 6, 7 m인 온실에서 가지주로 ø25 파이프를 2.4 m의 간격으로 설치하면 기본 구조물이 받는 적설하중 이외에 각각 25.3, 18.4, 13.9 cm의 적설심을 추가적으로 지지할 수 있는 것으로 나타났다. 그러나 폭이 각각 8, 9, 10 m인 온실의 경우에 내설성을 증대시키기 위해서는 서까래 골조 자체를 ø32 파이프로 바꾸어야 할 것으로 판단되며, 이 경우 가지주로 보강하면 안전적설심은 각각 30.1, 24.1, 19.4 cm까지 증가시킬 수 있는 것으로 나타났다. The pipe framed and arch shape plastic greenhouse, which is the most popular greenhouse in Korea, is relatively weak in snowdrift. Reinforcement of rigid frame or column is required to reduce the damage from heavy snow in this type. But additional rigid frames or columns decrease light transmissivity or workability, and increase construction cost. So it is desirable to prepare some temporary poles and to install them when the warning of heavy snow is announced. This study was carried out to develop the temporary pole supporting system using galvanized steel pipes for plastic housing and to evaluate the safe snow load on a temporary pole. A pipe connector, which is inserted in the top of pipe used in the temporary pole and supports the center purline, was designed and manufactured to be able to carry the upper loads safely. And a bearing plate was safely designed and manufactured in order to carry the loads acting on it to the ground. When temporary poles of ø25 pipe are installed at 2.4m interval, it shows that the single span plastic greenhouses with 5∼7 m width are able to support the additional snow depth of 13.9∼25.3 cm beyond the snow load supported by main frame.

      • KCI등재

        온실의 냉난방부하 산정을 위한 외부기상자료 비교분석

        남상운,신현호,서동욱 (사) 한국생물환경조절학회 2014 시설원예‧식물공장 Vol.23 No.3

        기상청에서 제공하는 전체 기상자료와 평년값 자료 및태양에너지학회에서 제공하는 표준기상데이터를 이용하여 위험률별 난방설계용 외기온과 상대습도, 냉방설계용건구온도, 습구온도 및 일사량 자료를 분석하였다. 표준기상데이터는 평균에 가장 가까운 대표성을 갖는 1개년의 데이터로 가공 처리한 매시간별 기상자료이고, 평년값 자료는 30년(1981~2010년) 평균 일별 기상자료이며,전체 기상자료는 평년값과 동일기간의 매시간별 기상자료이다. 일부 분석방법은 평년값 자료를 이용하는 경우도 있지만 대부분 매시간별 기상자료가 필요하고 대표성을 갖기 위해서는 표준기상데이터를 이용하는 것이 가장적합하다. 그러나 현재 표준기상데이터는 서울과 6대 광역시 등 7개 지역만 제공되고 있기 때문에 전국을 커버할 수 있는 지역별 온실 환경설계용 기상자료의 구축에는 전체 기상자료를 이용할 수밖에 없다. 따라서 본 연구에서는 표준기상데이터가 제공되고 있는 7개 지역을대상으로 전체 기상자료 및 평년값 자료를 이용한 방법으로 분석하여 표준기상데이터로 구한 값과 비교 검토하였다. 위험률별 설계 기상자료는 전체 기상자료를 이용하여 구한 평균값이 표준기상데이터로 구한 결과와 잘일치하였다. 따라서 표준기상데이터가 없는 지역의 위험률별 설계용 기상자료는 전체 기상자료를 이용하여 구하고, 전체자료 기간의 평균값을 온실의 환경설계 기준으로 사용하며, 최대값과 최소값을 제공함으로써 참고자료로 활용할 수 있도록 하는 것이 합리적인 방법으로 판단된다. 최근의 기후변화 문제로 냉난방 설계기온의 지속적인 변화가 예상되므로 이에 대응하기 위해서는 전문가들로 구성된 온실설계위원회와 같은 기구의 설치가 절실히 요청된다. 위원회에서는 자료기간 및 분석방법에대한 기준을 설정하고, 최소한 10년 간격의 정기적인 검토를 통하여 기상자료를 분석하고 온실설계기준 및 가이드라인을 제공할 필요가 있다. Standard weather data available to greenhouse environmental design are limited in most regions of thecountry. So, instead of using standard weather data, in order to find the method to build design weather data forgreenhouse heating and cooling, design outdoor weather conditions were analyzed and compared by TAC methodand frequency analysis using climatological normal and thirty years from 1981 to 2010 hourly weather data providedby KMA and standard weather data provided by KSES. Average TAC values of outdoor temperature, relativehumidity and insolation using thirty years hourly weather data showed a good agreement with them using standardweather data. Therefore, in regions which are not available standard weather data, we suggest that design outdoorweather conditions should be analyzed using thirty years hourly weather data. Average of TAC values derived fromevery year hourly weather data during the whole period can be established as environmental design standards, andalso minimum and maximum of them can be used as reference data.

      • KCI등재

        이류체 포그 냉방시스템의 제어알고리즘 개발

        남상운,김영식,성인모 (사) 한국생물환경조절학회 2013 시설원예‧식물공장 Vol.22 No.2

        In order to develop the efficient control algorithm of the two-fluid fogging system, cooling experimentsfor the many different types of fogging cycles were conducted in tomato greenhouses. It showed that the coolingeffect was 1.2 to 4.0℃ and the cooling efficiency was 8.2 to 32.9% on average. The cooling efficiency with fogginginterval was highest in the case of the fogging cycle of 90 seconds. The cooling efficiency showed a tendency toincrease as the fogging time increased and the stopping time decreased. As the spray rate of fog in the two-fluid foggingsystem increased, there was a tendency for the cooling efficiency to improve. However, as the inside airapproaches its saturation level, even though the spray rate of fog increases, it does not lead to further evaporation. Thus, it can be inferred that increasing the spray rate of fog before the inside air reaches the saturation level couldmake higher the cooling efficiency. As cooling efficiency increases, the saturation deficit of inside air decreased andthe difference between absolute humidity of inside and outside air increased. The more fog evaporated, the differencebetween absolute humidity of inside and outside air tended to increase and as the result, the discharge of vapordue to ventilation occurs more easily, which again lead to an increase in the evaporation rate and ultimately increasein the cooling efficiency. Regression analysis result on the saturation deficit of inside air showed that the foggingtime needed to change of saturation deficit of 10 g · kg−1 was 120 seconds and stopping time was 60 seconds. But inorder to decrease the amplitude of temperature and to increase the cooling efficiency, the fluctuation range of saturationdeficit was set to 5 g · kg−1 and we decided that the fogging-stopping time of 60-30 seconds was more appropriate. Control types of two-fluid fogging systems were classified as computer control or simple control, and theircontrol algorithms were derived. We recommend that if the two-fluid fogging system is controlled by manipulatingonly the set point of temperature, humidity, and on-off time, it would be best to set up the on-off time at 60-30 seconds in time control, the lower limit of air temperature at 30 to 32℃ and the upper limit of relative humidity at85 to 90%. 최근 국내에 많이 보급되고 있는 이류체 포그 냉방시스템의 효율적인 제어알고리즘을 개발하기 위하여 다양한 조건의 분무사이클을 설정하여 토마토재배 온실에서냉방실험을 실시하였다. 냉방효과는 평균 1.2~4.0℃를보였고, 냉방효율은 평균 8.2~32.9%로 나타났다. 분무간격에 따른 실험에서 90초 분무사이클의 냉방효율이 가장 높았고, 대체로 분무시간이 길수록, 정지시간이 짧을수록 냉방효율이 높게 나타났다. 이류체 포그시스템의분무량이 증가할수록 냉방효율이 높아지는 경향을 찾을수 있었다. 그러나 분무량을 증가시키더라도 내부공기가포화상태에 가까워지면 더 이상 증발이 일어나지 않으므로 내부공기가 포화상태에 도달하기 전까지 분무량을 증대시키는 방법으로 냉방효율을 높일 수 있을 것으로 판단된다. 냉방효율이 증가함에 따라 실내공기의 포차는감소하였고 실내외 절대습도 차이는 증가하는 경향을 보였다. 포그의 증발량이 증가할수록 실내와 실외의 절대습도 차이는 커지고, 이에 따라 환기에 의한 수증기 배출이 잘 되어 다시 증발효율을 상승시키므로 냉방효율이높아지는 순환구조를 갖게 되는 것으로 판단된다. 분무시간과 정지시간에 따른 실내공기의 포차변화를 회귀분석한 결과 10g · kg−1의 포차 변화에 필요한 분무시간은120초, 정지시간은 60초로 나타났다. 그러나 온도의 진동폭을 줄이고 냉방효율을 높이기 위해서는 포차의 변동범위를 5g · kg−1으로 설정하여 60초 분무, 30초 정지가더 적당할 것으로 판단된다. 이류체 포그시스템의 제어방식을 컴퓨터 제어시스템과 현재 보급되고 있는 간편제어시스템으로 분류하여 제어알고리즘을 유도하였다. 자연환기 온실에서 간편 제어시스템을 사용한다면 분무사이클을 60초 on, 30초 off로 설정하고 온도하한은 30~32℃, 습도상한은 85~90%로 설정할 것을 제안한다.

      • KCI우수등재

        간척지 설치 온실의 난방부하 특성 분석

        남상운,신현호,Nam, Sang Woon,Shin, Hyun Ho 한국농공학회 2017 한국농공학회논문집 Vol.59 No.6

        The purpose of this study was to provide basic data for development of environmental design technology for greenhouses constructed in reclaimed lands. We analyzed the climatic conditions around seven major reclaimed land areas in Korea, which have a plan to install advanced horticultural complexes. The characteristics of heating load through the thermal environment measurement of the greenhouse in Saemangeum were analyzed. The part to be applied to the environmental design of the greenhouses in reclaimed lands were reviewed. The overall heat transfer coefficient of the experimental greenhouse with the aluminum screen and multi-layer thermal curtain averaged $3.79W/m^2^{\circ}C$. It represents a 44 % heat savings rate compared with plastic greenhouses with a single covering, which was significantly lower than that of the common greenhouses with 2-layer thermal curtains. This is because the experimental greenhouse was installed on reclaimed land and wind was stronger than the inland area. Among the total heating load, the transmission heat loss accounted for 96.4~99.9 %, and the infiltration loss and the ground heat exchange were low. Therefore, it is necessary to take countermeasures to minimize the transmission heat loss for greenhouses constructed in reclaimed lands. As the reclaimed land is located on the seaside, the wind is stronger than the inland area, and the fog is frequent. Especially, Saemangeum area has 2.6 times stronger wind speed and 3.4 times longer fog duration than the inland area. In designing the heating systems for greenhouses in reclaimed lands, it is considered that the maximum heating load should be calculated by applying the wind coefficient larger than the inland area. It is reasonable to estimate the operation cost of the heating system by applying the adjustment factor 10 % larger than the average in calculating the seasonal heating load.

      • KCI등재

        다연동 플라스틱 온실의 자연환기성능 평가

        남상운,김영식,서동욱 (사) 한국생물환경조절학회 2013 생물환경조절학회지 Vol.22 No.1

        Environmental measurements in the many different types of horticultural farms were carried out to evaluatethe ventilation performance for multi-span plastic greenhouses according to the eaves height, the number ofspans, the existence of side wall vents and the position of roof vents. Hydroponic tomatoes were being cultivated inall experimental greenhouses, and ventilation rates of the greenhouses were analyzed by the heat balance method. Itshowed that the ventilation rate in the greenhouse with 4 m eaves height increased about 22% compared to the greenhousewith 2 m eaves height. The ventilation rate in the greenhouse with 9 spans decreased about 17% compared tothe greenhouse with 5 spans. In the greenhouse with 9 spans, if there were no side wall vents, the ventilation rateshowed about a third of the case that side wall vents were open. Overall, as the eaves height was higher and the numberof spans was smaller in multi-span greenhouses, the natural ventilation performance was better. And the ventilationperformance was best in the greenhouse which the eaves height was high and the position of roof vents wasridge, not gutter. Therefore, in order to maximize the natural ventilation performance, multi-span plastic greenhousesneed to improve their structures such as that make the eaves height higher, place the roof vents on the ridge, installthe side wall vents as much as possible, and the number of spans is limited to about 10 spans. 측고, 연동수, 측창의 유무 및 천창의 위치에 따른 다연동 온실의 환기성능을 평가하기 위하여 다양한 유형의 연동 플라스틱 온실을 대상으로 실제 농가의 재배현장에서 환경계측 실험을 수행하였다. 실험 대상 온실은 모두토마토를 수경재배하고 있는 농가였으며, 열수지 방법으로 환기율을 비교 분석하였다. 측고가 4m인 온실은 측고가 2m인 온실에 비하여 22% 정도의 환기율이 증가하는 것으로 나타났다. 9연동 온실은 5연동 온실에 비하여17% 정도의 환기율이 감소하는 것으로 나타났다. 9연동온실에서 측창이 없는 경우에는 측창을 설치한 경우 보다 환기율이 1/3 정도로 낮게 나타났다. 전체적으로 다연동 온실의 환기성능은 측고가 높을수록 좋고, 연동수가 많을수록 떨어지며, 측창이 없으면 현저하게 저하하는 것으로 나타났다. 또한, 측고가 높고 천창을 용마루에 설치한 경우의 환기성능이 가장 우수한 것으로 나타났다. 따라서 다연동 온실의 자연환기 성능을 극대화하기 위해서는 온실의 측고는 높이고, 지붕 환기창의 위치는 곡부가 아니라 용마루에 설치하며, 측창을 반드시 설치하고, 연동수는 10연동 내외로 제한하는 등의 구조개선이 필요하다.

      • 아치형 온실의 자연환기 및 차광방법 개선 연구

        남상운 안성산업대학교 1995 論文集 Vol.27 No.-

        Arched pipe greenhouse using plastic film is very popular in Korea because it has a simple structure and less cost than any other greenhouses. Although ti has a main advantage of easy construction, ti has some disadvantage of poor ventilation and uneven light transmission. In order to overcome the problems, large scale single-span pipe greenhouses have been widely popularized. But performance of natural ventilation is very poor because their structures are difficult to in stall the roof vent. Therefore, this study was conducted to improve thermal environment during high temperature season through roof vent installation and reformed shading method for large arched single-span pipe greenhouses. Natural ventilation characteristics with roof vent existence were analyzed by using steady state thermal balance model and gravitational ventilation equation. A case study on the effect of roof vent installation was carried out, and model structures for roof vent installation in large single-span pipe greenhouse were suggested. Besides, greenhouse air temperature difference with shading method was analyzed by the simulation model using PCSMP.

      • KCI등재

        아치형 단동온실의 지붕환기구조 및 천창효과

        남상운 충남대학교 농업과학연구소 2001 농업과학연구 Vol.28 No.2

        온실재배에 있어서 가장 경제적인 환경조절 방법은 자연환기에 의한 것이므로 온실의 자연환기 성능을 극대화하는 것은 매우 중요하다. 온실의 자연환기 성능을 극대화하기 위해서는 지붕환기창의 설치가 중요한데, 아치형 단동 온실의 경우에는 천창을 설치하기 어려운 구조로 되어 있어서 대부분의 농가가 측창만 설치하여 운영하고 있다. 본 연구에서는 아치형 단동 온실의 지붕에 환기창 설치를 장려하기 위한 일환으로 사례조사와 효과분석을 실시하였다. 아치형 단동 온실의 지붕환기구조 실태조사결과 폭 5∼8m의 소형 온실에서는 플라스틱으로 제작된 원형 및 굴뚝형 환기창을, 폭 12∼18m의 대형온실에서는 철재 파이프를 덧붙인 양권취식을 많이 사용하고 있었다. 지붕환기차설치 온실과 관행의 권취식 측창만 설치된 온실에 대한 대조 실험 결과 비록 적은 면적의 지붕환기창을 설치하였지만 온도하강 1℃ 이상의 천창 환기 효과가 있었으며, 지붕환기를 실시함으로써 온도분포를 보다 균일하게 할 수 있는 것으로 나타났다. 지붕환기창을 설치함으로서 얻을 수 있는 온도상승 억제효과는 일사량과 풍속조건에 따라 뚜렷한 차이를 보이며, 풍속이 낮은 경우에 효과가 커지는 것을 확인할 수 있었다. 환기창의 개폐순서에 따른 전체적인 온도 하강의 차이는 없으나, 환기로 온도를 제어하는 경우에는 실내온도가 설정온도보다 높을 때는 천창을 열은 후 측창을 열고, 반대의 경우에는 측창을 닫은 후 천창을 닫는 것이 바람직한 것으로 판단되었다. It is difficult to install a ventilation window on the roof of single span greenhouses of arch shape. Investigation on the roof ventilation structures for those greenhouses was conducted. In small greenhouses with spans of 5 to 8 m, circular or chimney type ridge vents made of plastic were employed. In large greenhouses with spans of 12 to 18 m, even span roll-up ridge vents made of steel pipe were employed. The effect of roof ventilation was evaluated by comparative experiments between greenhouse installing ridge vents and having controlled side vents only. Roof ventilation contributed greatly to restraint of temperature rise and maintenance of uniform temperature distribution in greenhouses. And ventilation efficiency was analyzed by experiments on the opening and closing operation of the ridge and side vent. There were no temperature differences according to opening and closing sequence of ventilation window. But for greenhouse temperature control by ventilation, it is desirable to open side vents after ridge vents and to close ridge vents after side vents.