RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSKCI등재

        동맥혈 채혈후 시간 경과 및 온도 변화가 가스분압 및 PH 에 미치는 영향에 관한 연구

        김동수,이승환,김건식,강화자,신광일,여민구 대한마취과학회 1989 Korean Journal of Anesthesiology Vol.22 No.6

        Blood gas samples are highly susceptible to preanalytic error due to improper methods of obtaining or handling the sample prior to delivery to the laboratory. The errors in the measurement of blood gas analysis are currently derived from the exposure of sample to atmosphere, effects of anticoagulant itself, temperature difference between the measuring electrode and drawn blood and the delay in running the sample. To study the effects of the delay in measuring the sample and the temperature difference between the measuring electrode and drawn blood on values of blood gases and pH, we analyzed the arterial sampling from the 24 patients who were taking elective surgery or on his/her recovery period with indwelling arterial catheter. The plastic sampling syringes were kept at 4。C (refrigerator) or 22。-24。C (room temperature) and analyzed at regular intervals (1, 10, 30, 60,120 min) for 120 minutes. The following results were obtained: 1) When the arterial blood drawn from the anesthetized patients were stored 4。C, partial pressure of oxygen (PaO₂) decreased significantly after 20 min, whereas those stored at room temperature decreased significantly after 10 min. 2) When the arterial blood drawn from the recovery patients were stored at 4。C, PaO₂ did not decrease significantly through the experimental period of 120 min. Although those stored at room temperature did not decrease significantly through the period of 120 min. 3) Partial pressure of carbon dioxide in the arterial blood (PaCO₂,) drawn from the anesthetized patients increased significantly by 120 min. at 4。C, whereas those at room temperature increased significantly after 20 min. 4) PaCO₂, of the recovery patients increased signigicantly by 120 min. at 4。C, whereas those at room temperature increased significantly after 30 min. 5) pH of the arterial blood drawn from either anesthetized or recovery patients decreased significantly by 120 min. at 4。C, whereas those at room temperature decreased significantly after 60 min. 6) No significant changes al oxygen saturation (SaO₂) and content (CaO₂) were noted in either anesthetized or recovery. patients in accordance with time elapsed at 4。C or room temperature. In summary, as the changes of PO₂ in particular higher than physiologic PO₂ and PCO₂ in the arterial blood stored at room temperature are significant in accordance with the delay in measuring, it would be advisable to analyze the sample in a short period of time or to store it in a cool place when the measuring will be delayed.

      • Comparative evaluation of the algorithms for parametric mapping of the novel myocardial PET imaging agent <sup>18</sup> F-FPTP

        Kim, Ji Who,Seo, Seongho,Kim, Hyeon Sik,Kim, Dong-Yeon,Lee, Ho-Young,Kang, Keon Wook,Lee, Dong Soo,Bom, Hee-Seung,Min, Jung-Joon,Lee, Jae Sung Springer Japan 2017 Annals of nuclear medicine Vol.31 No.6

        <P><B>Objective</B></P><P>(<SUP>18</SUP>F-fluoropentyl)triphenylphosphonium salt (<SUP>18</SUP>F-FPTP) is a new promising myocardial PET imaging tracer. It shows high accumulation in cardiomyocytes and rapid clearance from liver. We performed compartmental analysis of <SUP>18</SUP>F-FPTP PET images in rat and evaluated two linear analyses: linear least-squares (LLS) and a basis function method (BFM) for generating parametric images. The minimum dynamic scan duration for kinetic analysis was also investigated and computer simulation undertaken.</P><P><B>Methods</B></P><P><SUP>18</SUP>F-FPTP dynamic PET (18 min) and CT images were acquired from rats with myocardial infarction (MI) (<I>n</I> = 12). Regions of interest (ROIs) were on the left ventricle, normal myocardium, and MI region. Two-compartment (<I>K</I><SUB>1</SUB> and <I>k</I><SUB>2</SUB>; 2C2P) and three-compartment (<I>K</I><SUB>1</SUB>–<I>k</I><SUB>3</SUB>; 3C3P) models with irreversible uptake were compared for goodness-of-fit. Partial volume and spillover correction terms (<I>V</I><SUB><I>a</I></SUB> and <I>α</I> = 1 − <I>V</I><SUB><I>a</I></SUB>) were also incorporated. LLS and BFM were applied to ROI- and voxel-based kinetic parameter estimations. Results were compared with the standard ROI-based nonlinear least-squares (NLS) results of the corresponding compartment model. A simulation explored statistical properties of the estimation methods.</P><P><B>Results</B></P><P>The 2C2P model was most suitable for describing <SUP>18</SUP>F-FPTP kinetics. Average <I>K</I><SUB>1</SUB>, <I>k</I><SUB>2</SUB>, and <I>V</I><SUB><I>a</I></SUB> values were, respectively, 6.8 (ml/min/g), 1.1 (min<SUP>−1</SUP>), and 0.44 in normal myocardium and 1.4 (ml/min/g), 1.1 (min<SUP>−1</SUP>), and 0.32, in MI tissue. Ten minutes of data was sufficient for the estimation. LLS and BFM estimations correlated well with NLS values for the ROI level (<I>K</I><SUB>1</SUB>: <I>y</I> = 1.06<I>x</I> + 0.13, <I>r</I><SUP><I>2</I></SUP> = 0.96 and <I>y</I> = 1.13<I>x</I> + 0.08, <I>r</I><SUP><I>2</I></SUP> = 0.97) and voxel level (<I>K</I><SUB>1</SUB>: <I>y</I> = 1.22<I>x</I> − 0.30, <I>r</I><SUP><I>2</I></SUP> = 0.90 and <I>y</I> = 1.26<I>x</I> + 0.00, <I>r</I><SUP><I>2</I></SUP> = 0.92). Regional distribution of kinetic parametric images (<I>αK</I><SUB>1</SUB>, <I>K</I><SUB>1</SUB>, <I>k</I><SUB>2</SUB>, <I>V</I><SUB>a</SUB>) was physiologically relevant. LLS and BFM showed more robust characteristics than NLS in the simulation.</P><P><B>Conclusions</B></P><P>Fast kinetics and highly specific uptake of <SUP>18</SUP>F-FPTP by myocardium enabled quantitative analysis with the 2C2P model using only the initial 10 min of data. LLS and BFM were feasible for estimating voxel-wise parameters. These two methods will be useful for quantitative evaluation of <SUP>18</SUP>F-FPTP distribution in myocardium and in further studies with different conditions, disease models, and species.</P><P><B>Electronic supplementary material</B></P><P>The online version of this article (doi:10.1007/s12149-017-1171-6) contains supplementary material, which is available to authorized users.</P>

      • SCOPUSKCI등재

        COPA(cuffed oropharyngeal airway)를 이용한 마취 유도 시 근이완제 사용 유무에 따른 반응

        김상태,배진호,김상범,임승운,민병상,신영덕 대한마취과학회 2000 Korean Journal of Anesthesiology Vol.38 No.3

        Background : COPA (cuffed oropharyngeal airway) is a convenient device for airway management in patients undergoing general anesthesia for elective surgery in supine position. It causes less pharyngeal trauma than LMA(Laryngeal mask airway). The purpose of this study was to compare the effect of COPA with and without muscle relaxant. Methods : Forty patients with ASA physical status I and II for elective surgery were randomly assigned to two groups. Anaesthesia was induced with propofol (2 mg/kg) and vecuronium (1.5 mg/kg) and was administered intravenously in Group I but not in Group II. Mask ventilation was done for 5 min with 0: 5 L/min. COPA was placed and heart rate, and systolic, mean, diastolic blood pressure and peak inspiratory pressure were measured at 1 min interval for 5 min. Anaesthesia was maintained with pro- pofol 150 ㎍/kg/min, fentanyl 1 ㎍/kg/hr, O_2 2 L/min and N_2O 2 L/min. Results : There were no significant differences between Group I and Group II in heart rate, systolic, mean and dstolic blood pressure. PIP (Peak inspiratory pressure) was increased and hiccups occurred significantly (p $lt; 0.05) in Group II. Complete airway obstruction occurred in one patient of Group I and severe coughing, body movements and gagging occurred during induction and insertion in Group II. conclusions : With the use of appropriate muscle relaxant, we can use COPA without increased inspiratory pressure or significant complication. (Korean J Anesthesiol 2000; 38: 399~403)

      • Dose re-evaluation in personal dosimetry using the phototransferred thermoluminescence method of LiF:Mg,Cu,Si TLD

        Kim, Hyoungtaek,Kim, Min Chae,Lee, Jungil,Chang, Insu,Lee, Seung Kyu,Kim, Jang-Lyul Elsevier 2018 Radiation measurements Vol.118 No.-

        <P><B>Abstract</B></P> <P>Phototransferred thermoluminescence (PTTL) characteristics of LiF:Mg,Cu,Si, developed by the Korea Atomic Energy Research Institute, are presented as part of a simple and reliable method for dose re-evaluation that is compatible with routine personal dosimetry services. A 4.5 mm diameter 0.8 mm thick pellet-type thermoluminescence dosimeter (TLD) was used after dual-step thermal annealing at 300 °C for 10 min, and then at 260 °C for 10 min, in order to obtain thermal stability. For optimal UV illumination, samples were placed under a 254 nm ultraviolet (UV) lamp for 90 min. The PTTL signal was only lower than 2% that of the TL because of low residual signals in high-temperature deep traps. The difference of the PTTL signals between samples appeared up to two times, indicating high variation in the charge density of the deep traps between samples. Various thermal treatments were performed after each PTTL measurement to remove the residual PTTL signal. UV exposure at 250 °C for 20 min fully reset the residual PTTL signals to the same level as that after dual-step annealing. No degradation of the TL peak from repeated thermal treatments was observed until after the eighth treatment when a decrease was noticeable. The measured dose response of PTTL in the range of 1.14–51.3 mGy showed good linearity. The zero dose and minimal detectable dose of the PTTL were 1.36 ± 0.51 mGy and 1.53 mGy, respectively. The attenuation of the PTTL signal resulting from successive TL measurements was recorded to provide a correction factor for quarterly recorded TL measurements applicable to the dose re-evaluation of TLDs in routine personal dosimetry services.</P> <P><B>Highlights</B></P> <P> <UL> <LI> Dose re-evaluation using LiF:Mg,Cu,Si TLD is possible. </LI> <LI> Phototransferred thermoluminescence of LiF:Mg,Cu,Si was characterized. </LI> <LI> Heat treatment is required to remove residual phototransferred thermoluminescence. </LI> </UL> </P>

      • SCOPUSKCI등재

        A comparison of Min’s glasses and conventional occlusion therapy in the treatment of amblyopic children: a prospective study

        Byung Moo Min,Seung Young Kim,Kil Hwan Ko,Seong Bok Lee 대한안과학회 2000 Korean Journal of Ophthalmology Vol.14 No.1

        Min’s glasses are specially manufactured in order to enhance the satisfaction of the wearer and increase treatment effectiveness. We compared the effectiveness of Min’s glasses with that of conventional occlusion therapy in amblyopic pediatric patients. We prospectively studied 60 amblyopic patients. For four to 30 months, 24 of the patients were treated with conventional patch occlusion (patch group) and 36 of them were treated with Min’s glasses (glasses group). We compared the improvement in visual acuity and the treatment compliance between both groups, according to age (over six and less than six), sex, type of amblyopia, and the duration of treatment. Sixteen patients (66.7%) in the patch group and 32 patients (88.9%) in glasses group showed improvement in visual acuity (p=0.002). The pre-treatment average log MAR acuity was 0.56±0.25 in the patch group, and 0.59 ±0.25 in the glasses group. The average improvement in visual acuity was a 0.17 log MAR score in the patch group, and a 0.31 log MAR score in the glasses group (p=0.004). Compliance was 59.54% in the patch group and 83.44% in the glasses group (p=0.012). The pre-treatment average log MAR acuity was 0.49 ± 0.23 for children over six years of age in the patch group, and 0.58±0.28 for children over six years of age in the glasses group. For children over six years of age in the glasses group the improvement in visual acuity (0.29 log MAR score) was greater than for children over six years of age in the patch group (0.06 log MAR score) (p=0.0003). The pre-treatment average log MAR acuity was 0.55±0.22 for female patients in the patch group, and 0.60±0.25 for female patients in the glasses group. Female patients in the glasses group also showed a greater visual acuity improvement (0.29 log MAR score) than female patients in the patch group (0.14 log MAR score) (p=0.0028). However, there were no differences between the groups in patients less than six years of age and in male patients. In conclusion, Min’s glasses were more effective than conventional treatment with a patch in improving visual acuity and encouraging compliance in pediatric amblyopic patients, especially in children over six years of age and in girls.

      • KCI등재

        정신분열병에 대한 리스페리돈의 효과 및 안정성

        이민수,김용구,김영훈,연병길,오병훈,윤도준,윤진상,이철,정희연,강병조,김광수,김동언,김명정,김상훈,김희철,나철,노승호,민경준,박기창,박두병,백기청,백인호,손봉기,손진욱,양병환,양창국,우행원,이정호,이종범,이홍식,임기영,전태연,정영조,정영철,정인과,정인원,지익성,채정호,한상익,한선호,한진희,서광윤 大韓神經精神醫學會 1998 신경정신의학 Vol.37 No.1

        연구목적 : 본 시험의 목적은 임상시험 시작전에 연구자들을 대상으로 PANSS Workshop을 통하여 PANSS, ESRS에 대한 국내에서의 표준화 작업을 구축하고 새로운 정신병 치료제인 리스페리돈의 효과와 안정성을 재확인하여 리스페리돈 사용에 대한 적정화를 이루는데 있다. 연구방법 : 1996년 4월부터 1996년 9월까지 국내 39개 대학병원 정신과에 입원중인 혹은 증상이 악화되어 입원하는 정신분열병 환자 377명을 대상으로 다시설 개방 연구를 시행하였다. 1주일간의 약물 배설기간을 가진후, 리스페리돈을 8주간 투여하였고, 기준점, 1주, 2주, 4주, 그리고 8주후에 평가되었다. 용량은 제1일에는 리스페리돈 1mg씩 1일 2회, 제2일에는 2mg씩 1일 2회, 제3∼7일에는 3mg씩 1일 2회 투여하였다. 이후 환자의 임상상태에 따라 임의로 증량할 수 있으며, 최대 일일 16mg을 초과하지 않도록 하였다. 추체외로 증상을 조절하기 위한 투약을 허용하였다. 임상증상 및 부작용의 평가는 PANSS(Positive and Negative Syndrome Scale), CGI(Clinical Global Impression) 그리고 ESRS(Extrapyramidal Symptom Rating Scale)을 사용하였다. 연구결과 : 377명중 343명(91%)이 8주간의 연구를 완결하였다. 치료 종결시점인 8주후 PANSS 총점수가 20% 이상 호전된 경우를 약물 반응군으로 정의할때, 약물반응군은 81.3%였다. 리스페리돈에 반응하는 예측인자로는 발병연령, 이전의 입원 횟수, 유병기간이 관련 있었다. 리스페리돈은 1주후부터 PANSS양성, 음성, 및 일반정신병리 점수상에 유의한 호전을 보여 효과가 빨랐다. CGI의 경우도 기준점에 비해 1주후부터 유의한 감소를 나타내었다. ESRS의 경우, 파킨슨 평가점수는 기준점과 비교해 투여 1주, 2주, 4주후 유의하게 증가되었다가 8주후 기준점과 차이가 없었다. Dystonia 평가점수는 1주후만 유의한 증가를 보였으며, dyskinesia 평가점수는 유의한 차이가 없었다. 혈압, 맥박수의 생명징후 및 일반 혈액학 검사, 생화학적 검사, 심전도 검사에서 유의한 변화는 없었다. 결 론 : 이상의 다시설 개방 임상 연구를 통해 리스페리돈은 정신분열병 환자에서 양성증상뿐만 아니라 음성증상 및 전반적인 증상에도 효과적인 것으로 사료된다. 보다 명확한 평가를 위해서는 다른 항정신병약물과의 이중맹검 연구가 필요할 것으로 생각되며, 또한 장기적 치료에 대한 평가도 함께 이루어져야 하겠다. Objective : The purpose of this study was to investigate the efficacy and safety of risperidone in the treatment of Korean schizophrenic patients. Method : This multicenter open study included 377 schizophrenic patients drawn from 39 university hospitals. After a wash-out period of 1 week, the schizophrenic patients were treated with risperidone for 8 weeks and evaluated at 5 points ; at baseline, and 1, 2, 4 and 8 weeks of treatment. The dose was increased from 2mg/day(1mg twice daily) to 6mg/day(3mg twice daily) during the first week and adjusted to a maximum of 16mg/day over the next 7 weeks according to the patient's clinical response. Medication to control extrapyramidal symptoms was permitted. The psychiatric and neurological status of the patients was assessed by PANSS, CGI, and ESRS scales. Results : 343(91%) of 377 patients completed the 8-week trial period. Clinical improvement, as defined by a 20% or more reduction in total PANSS score at end point, was shown by 81.3% of patients. The predictors of response to risperidone were associated older age, shorter duration of illness, fewer previous hospitalization. Risperidone had rapid onset of action ; a significant decrease of the total PANSS and three PANSS factor(positive, negative, general), and CGI was already noticed at the end of first week. For the ESRS, parkinsonism rating scores were significantly increased until week 4 comparing with baseline. Dystonia rating scores were significantly increased until week 1, and dyskinesia rating scores were not significantly changed during the study. Laboratory parameters including vital sign, EKG, hematological, and biochemical values showed no significant changes during the trial. Conclusions : This study suggests that risperidone is generally safe and effective against both the positive and negative symptoms in our group of patients.

      • Pseudomonas sp. BCNU 171균에서의 유기용매 shock반응과 heat shock반응의 연관성

        이승범,김미림,정미연,박정욱,김민정,주우홍 Institute of Genetic Engineering Changwon National 1999 Gene and Protein Vol.3 No.1

        The response of Pseudomonas sp. BCNU 171 to various forms of stress was examined by using O'Farrell two-dimensional gel electrophoresis. The toluene resistance of mid-growth cells of Pseudomonas sp. BCNU 171 grown at 30℃ was enhanced by exposing the cells to a prior toluene shock in the presence of 0.05% toluene for 30 min. The heat tolerance of the cell was also induced by the same condition. Individual protein expression was examined at 30 min and 60 min by silver staining after the addition of 0.05%(v/v) toluene to mid-growing cultures of the strain BCNU 171. The toluene stress response increased the expression of eighteen proteins between 30 and 60 min toluene exposure. At 60 min after toluene addition, a toluene specific protein was detected. A few proteins induced by toluene and heat were overlapped on 2D-PAGE.

      • KCI등재

        건강한 청년의 단시간 공해노출과 일회성 운동이 폐기능과 생리반응에 미치는 영향

        김민주(Min-Joo Kim),이대택(Dae-Taek Lee),송국섭(Gook-Sup Song),방승기(Seung-Ki Pang) 한국생활환경학회 2015 한국생활환경학회지 Vol.22 No.1

        This study examined whether an acute exercise during a short-term exposure to a polluted environment affected pulmonary function and physiological responses in healthy young adults. Thirteen men (mean = 22.4 yrs) were randomly exposed to a polluted air (PA) or to clean air (CA) in a chamber. During the exposure, they rested for 30 min followed by a bench stepping exercise (40 cm height, 120 bpm) for 10 min. And they recovered from the exercise for 15 min in the chamber. The pulmonary function, heart rate, blood lactate, and blood pressure were measured during the exposure. At the end of 30 min resting, peak expiratory flow rate (PEFR) was higher in PA than CA. Immediately after the exercise, forced expiratory volume at 1 sec (FEV1) was higher in PA than CA. At 15th min of recovery, forced vital capacity, FEV1, and PEFR were significantly higher in PA than CA. No differences in cardiovascular and blood lactate responses were noticed. The results suggest that an acute intensive physical work out with breathing of volatile organic compounds induced changes of pulmonary function but not physiological adjustments.

      • KCI등재

        강변여과에서 파일럿규모 수평집수관의 수두분포 연구

        정재민(Jae Min Jeong),박재영(Jae Young Park),이종진(Jong Jin Lee),김용운(Yong Woon Kim),김승현(Seung Hyun Kim) 大韓環境工學會 2013 대한환경공학회지 Vol.35 No.5

        강변여과용 수평집수관을 모사하는 파일럿 규모의 모래통 실험을 수행하였으며, 다양한 출구유속에 대한 수평집수관에서의 수두분포를 구하였다. Kim24)이 수행한 실험실 규모의 수평집수관에서의 손실수두에 Kim25)이 개발한 이론 즉, 작은 규모의 수평집수관에서의 손실수두로부터 큰 집수관의 손실수두를 계산하는 방법을 적용하여 본 연구의 관측치와 비교함으로써 Kim25)의 이론이 타당함을 알 수 있었다. 또한, 이들의 이론을 적용하여 본 연구에서의 관측치로부터 실규모 집수관에서의 수두분포를 구하는 방안을 예를 들어 설명함으로써 강변여과의 수평집수관 설계방법을 제시하였다. A pilot-scale sand-box experiment simulating a lateral of collector well used in riverbank filtration was performed, and hydraulic head distributions along the lateral were measured according to the various drawdowns at the well. The results of this experiment were compared to the predicted values obtained using a theory previously developed by Kim25) in order for its validation. This theory predicts the head loss in a large-scale lateral given the loss in a small-scale one, and to have actual values for comparison, the results from a lab-scale experiment previously performed by Kim24) were employed. Comparing the experimental values to the extrapolated value indeed confirmed the validity of the theory. A procedure to determine the hydraulic head distribution of a practical-scale lateral was also presented applying the theory to the experimental result of this study in an effort to show the process of lateral design for riverbank filtration.

      • KCI등재

        이동형 스크러버를 이용한 암모니아 및 톨루엔의 제거 효율

        김재영 ( Jae-young Kim ),김장윤 ( Jang-yoon Kim ),이연희 ( Yeon Hee Lee ),김민선 ( Min Sun Kim ),김민수 ( Min-su Kim ),김현지 ( Hyun Ji Kim ),류태인 ( Tae In Ryu ),정재형 ( Jae Hyeong Jeong ),황승율 ( Seung-ryul Hwang ),김균 ( Ky 한국환경농학회 2018 한국환경농학회지 Vol.37 No.1

        본 연구는 국내에서 다량 취급되고 있는 암모니아 및 톨루엔을 흄 상태로 노출시킨 후 흡수/흡착방법을 달리한 이동형 스크러버를 이용해 각 유해화학물질의 제거효율을 비교 분석하였다. 이동형 스크러버는 기 개발된 장치를 개선하여 와류세정에 의한 흡수, 유입풍속 조절의 장점을 살리고, 활성탄 및 카본필터를 통한 기체상 유해화학물질의 흡착방법 도입을 통해 단점을 보완하였다. 개선된 장치는 기초성능평가를 통해 적정 제어풍속이 검증되었고, 5% 암모니아수 용액을 흄 상태로 노출시켜 후드 흡입부, 송풍기 배출부 및 세정기가 정상 작동함을 확인하였다. 흡수/흡착방법에 따른 암모니아 제거효율은 90분 경과 후 C≥PCA>SWA 순으로 가장 우수한 SWA 군의 노출 농도별 제거 효율은 시간이 경과할수록 노출 농도와 무관하게 배출 농도는 증가되었고, 세정액의 pH는 산성에서 염기성으로 변화되었다. 또한, 시간 경과에 따른 노출 농도 별 세정액의 pH 변화와 배출구 농도 변화 사이에 0.9429~0.9491 수준의 정의 상관관계를 나타내었다. 흡착방법에 따른 톨루엔의 제거 효율은 초기 10분 경과 후 배출구농도에서 C>CMA≥GCA 순을 나타내다 90분 경과까지 일정한 농도로 유지되었다. 가장 우수한 GCA 군의 노출 농도 별 제거 효율은 초기 10분 경과 시 노출 농도에 비례하여 배출 농도가 높은 경향이었다. 이와 같은 결과를 통해 개선된 이동형 스크러버는 중화반응에 의해 산성 또는 염기성 유해화학물질의 제거뿐 아니라, 활성탄 등의 흡착기능 개선을 통해 VOCs 제거에도 효과적이었다. 하지만, 실제 현장에서 활용이 가능하도록 세정액 pH를 지속적으로 유지하여 연속적으로 흡수 제거할 수 있는 방법과 노출되는 화학물질 농도와 흡착제의 관계에서 파괴점, 포화점, 흡착속도 등의 물리적인 요소가 추가적인 연구를 통해 도출되어야 할 것이다. BACKGROUND: The mobile vortex wet scrubber was developed to remove the harmful chemicals from accidental releases. However, there was a disadvantage that it was limitedly used for volatile organic compounds (VOCs) such as toluene according to the physicochemical properties. This study compared the removal efficiencies of an improved mobile scrubber on toluene and ammonia by applying diverse adsorption and absorption methods. METHODS AND RESULTS: The removal efficiencies on harmful chemicals were examined using various adsorption and absorption methods of water vortex process (C), phosphoric acid-impregnated activated carbon adsorption (PCA), pH-controlled water (pH 2.5) vortex process absorption with sulfuric acid (SWA) after ammonia exposure, granular activated carbon adsorption (GCA), and activated carbon mat adsorption (CMA) after toluene exposure. As a result, the best removal efficiency was shown in the SWA for ammonia and GCA for toluene. Also, the SWA and GCA methods were compared with different concentration levels. In the case of ammonia exposure (5, 10 and 25%), there was no difference by concentration levels, and the concentration in the outlet gradually increased, with pH change from acid to base. In the case of toluene exposure (50, 75 and 100%), the outlet concentration was higher relative to the exposure concentration in the initial 10 min, but the outlet concentration was remained steady after 10 min. CONCLUSION: The newly improved mobile scrubber was also effective in removing VOCs through adsorption techniques (activated carbon, activated carbon fiber, carbon mat filter etc.), as well as removing acid-base harmful chemicals by neutralization reaction.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼