Experimental and numerical study on the PSSDB system as two-way floor units
Marwan S. Al-Shaikhli,Wan Hamidon Wan Badaruzzaman,Ahmed W. Al-Zand 국제구조공학회 2022 Steel and Composite Structures, An International J Vol.42 No.1
This paper researches a lightweight composite structure referred to as the Profiled Steel Sheeting Dry Board (PSSDB). It is fundamentally produced by connecting a Profiled Steel Sheeting to Dry Board using mechanical screws. It is mainly employed as floor panels. However, almost all studies have focused on researching the one-way structural performance. Therefore, this study focuses on the bending behaviour of the two-way PSSDB floor system using both of Finite Element (FE) and Experimental analysis. Four panels were used in the experimental tests, and a mild steel plate has been applied at the bottom for two panels. For the FE process, models were created using ABAQUS software. 4 parametric studies have been utilized to understand the system’s influential elements. From the experimental tests, it was found that using Steel Plate shall optimize the two-way action of the system and depending on the type of dry board the improvement in stiffness may reach up to 38%. It was shown from the FE analysis that the dry board, profiled steel sheeting and steel plat can affect the system by up to 10 %, 17% and 3% respectively, while applying a uniform load demonstrate a better two-way action.
Flexural performance of cold-formed square CFST beams strengthened with internal stiffeners
Ahmed W. Al-Zand,W.H. Wan Badaruzzaman,Mustafa M. Ali,Qahtan A. Hasan,Marwan S. Al-Shaikhli 국제구조공학회 2020 Steel and Composite Structures, An International J Vol.34 No.1
The tube outward local buckling of Concrete-Filled Steel Tube (CFST) beam under high compression stress is still considered a critical problem, especially for steel tubes with a slender section compared to semi-compact and compact sections. In this study, the flexural performance of stiffened slender cold-formed square tube beams filled with normal concrete was investigated. Fourteen (14) simply supported CFST specimens were tested under static bending loads, stiffened with different shapes and numbers of steel stiffeners that were provided at the inner sides of the tubes. Additional finite element (FE) CFST models were developed to further investigate the influence of using internal stiffeners with varied thickness. The results of tests and FE analyses indicated that the onset of local buckling, that occurs at the top half of the stiffened CFST beam’s cross-section at mid-span was substantially restricted to a smaller region. Generally, it was also observed that, due to increased steel area provided by the stiffeners, the bending capacity, flexural stiffness and energy absorption index of the stiffened beams were significantly improved. The average bending capacity and the initial flexural stiffness of the stiffened specimens for the various shapes, single stiffener situations have increased of about 25% and 39%, respectively. These improvements went up to 45% and 60%, for the double stiffeners situations. Moreover, the bending capacity and the flexural stiffness values obtained from the experimental tests and FE analyses validated well with the values computed from equations of the existing standards.