RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Detection of Escherichia coli in Food Samples by Magnetosome-based Biosensor

        Sumana Sannigrahi,Shiva Kumar A,J. Mathiyarasu,K. Suthindhiran 한국생물공학회 2023 Biotechnology and Bioprocess Engineering Vol.28 No.1

        The rising cases of food poisoning and traveler’s diarrhea through Escherichia coli infection are a global concern. Magnetosome is biogenic magnetic nanoparticles extracted from magnetotactic bacteria and magnetosomebased biosensors offer simple and rapid detection of microbial pathogens. The current study demonstrates the application of a magnetosome-antibody complex-based biosensor for the detection of antigenic O-polysaccharide and E. coli from contaminated food samples. The magnetosome (1, 2 mg/mL)-antibody (0.8-200 μg/mL) complex was initially coupled with lipopolysaccharide (5 μg/mL) through antibody-antigen interaction. The magnetosome (1, 2 mg/mL)-antibody (0.8-200 μg/mL)-lipopolysaccharide (5 μg/mL) complexes were collected via external magnet and confirmed through spectroscopy studies. The magnetosome (1, 2 mg/mL)-antibody (0.8-200 μg/mL) complexes were applied to different concentration of lipopolysaccharide (0.01-50 μg/mL). The concentrated magnetosome (2 mg/ mL)-antibody (1.6 μg/mL) complex and lipopolysaccharide (0.1 μg/mL) were established in ELISA. Further, the magnetosome-antibody complex was applied on a screenprinted carbon electrode and stabilized through an external magnet. The least concentration of lipopolysaccharide (0.5 μg/mL) was determined in impedance. Further, the magnetosome-based biosensor was applied to various contaminated food samples- milk, water, and pineapple juice and the extracted lipopolysaccharide were selectively detected. The biosensor did not display any cross-reactivity and therefore exhibits specificity. The active E. coli (101 CFU/mL) from milk and water samples were also rapidly detected within 30 min by the developed biosensor. Furthermore, the field emission scanning electron microscope images confirmed the efficient detection of E. coli from the food sample.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼