RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Relationship Between Chloroquine or Hydroxychloroquine Use and Hearing Disorders: A Systematic Review and Meta-Analysis

        José Maria Renata,Ortega Jéssica da Silva,Baran Jordana Batista Correia,Lüders Débora,Gonçalves Claudia Giglio de Oliveira,Zeigelboim Bianca Simone,Taveira Karinna Veríssimo Meira,Polanski José Fernan 대한청각학회 2024 Journal of Audiology & Otology Vol.28 No.2

        Background and Objectives: Chloroquine and its analog hydroxychloroquine are derivatives of 4-aminoquinoline and are regularly used in the treatment of malaria and autoimmune diseases. Among the side effects of these drugs, alterations associated with the auditory system are frequently mentioned. Thus, the aim of this systematic review is to systematically review publications on hearing disorders and chloroquine or hydroxychloroquine use.Materials and Methods: Inclusion criteria were observational or interventional studies on audiological assessment in participants who were using chloroquine or hydroxychloroquine. The methodological quality was independently assessed by two reviewers using the Meta-Analysis of Statistics: assessment and review Instrument. The certainty of the evidence was assessed using the GRADE tool.Results: A total of 1,372 non-duplicate papers were screened, out of which 17 were included in the final qualitative synthesis, and 5 studies in the meta-analysis. The odds ratio for the two subgroups evaluated did not show significance with no heterogeneity between the effects observed between the different diseases (I<sup>2</sup>=0%) and obtaining the global estimate of 0.76 (95% confidence interval [CI]=0.41–1.39; <i>p</i>>0.05). Despite the inclusion of papers with different disease samples, the heterogeneity observed in the analysis was low (I<sup>2</sup>= 0%) and prediction interval (95% PI=0.32–1.80; p>0.05) remained close to that estimated by the CI (95% CI=0.41–1.39; <i>p</i>>0.05). The certainty of the evidence assessed by the GRADE tool was considered very low due to the risk of bias, indirect evidence, and imprecision.Conclusions: The findings of this study suggest that the use of chloroquine/hydroxychloroquine is not associated with hearing disorders.

      • SCOPUSKCI등재

        Augmented reality and dynamic infrared thermography for perforator mapping in the anterolateral thigh

        Cifuentes, Ignacio Javier,Dagnino, Bruno Leonardo,Salisbury, Maria Carolina,Perez, Maria Eliana,Ortega, Claudia,Maldonado, Daniela Korean Society of Plastic and Reconstructive Surge 2018 Archives of Plastic Surgery Vol.45 No.3

        Dynamic infrared thermography (DIRT) has been used for the preoperative mapping of cutaneous perforators. This technique has shown a positive correlation with intraoperative findings. Our aim was to evaluate the accuracy of perforator mapping with DIRT and augmented reality using a portable projector. For this purpose, three volunteers had both of their anterolateral thighs assessed for the presence and location of cutaneous perforators using DIRT. The obtained image of these "hotspots" was projected back onto the thigh and the presence of Doppler signals within a 10-cm diameter from the midpoint between the lateral patella and the anterior superior iliac spine was assessed using a handheld Doppler device. Hotspots were identified in all six anterolateral thighs and were successfully projected onto the skin. The median number of perforators identified within the area of interest was 5 (range, 3-8) and the median time needed to identify them was 3.5 minutes (range, 3.3-4.0 minutes). Every hotspot was correlated to a Doppler sound signal. In conclusion, augmented reality can be a reliable method for transferring the location of perforators identified by DIRT onto the thigh, facilitating its assessment and yielding a reliable map of potential perforators for flap raising.

      • KCI등재

        Augmented reality and dynamic infrared thermography for perforator mapping in the anterolateral thigh

        Ignacio Javier Cifuentes,Bruno Leonardo Dagnino,María Carolina Salisbury,María Eliana Perez,Claudia Ortega,Daniela Maldonado 대한성형외과학회 2018 Archives of Plastic Surgery Vol.45 No.3

        Dynamic infrared thermography (DIRT) has been used for the preoperative mapping of cutaneous perforators. This technique has shown a positive correlation with intraoperative findings. Our aim was to evaluate the accuracy of perforator mapping with DIRT and augmented reality using a portable projector. For this purpose, three volunteers had both of their anterolateral thighs assessed for the presence and location of cutaneous perforators using DIRT. The obtained image of these “hotspots” was projected back onto the thigh and the presence of Doppler signals within a 10-cm diameter from the midpoint between the lateral patella and the anterior superior iliac spine was assessed using a handheld Doppler device. Hotspots were identified in all six anterolateral thighs and were successfully projected onto the skin. The median number of perforators identified within the area of interest was 5 (range, 3–8) and the median time needed to identify them was 3.5 minutes (range, 3.3–4.0 minutes). Every hotspot was correlated to a Doppler sound signal. In conclusion, augmented reality can be a reliable method for transferring the location of perforators identified by DIRT onto the thigh, facilitating its assessment and yielding a reliable map of potential perforators for flap raising.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼