RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • A multifunctional micro-fluidic system for dielectrophoretic concentration coupled with immuno-capture of low numbers of <i>Listeria monocytogenes</i>

        Yang, Liju,Banada, Padmapriya P.,Chatni, Mohammad R.,Seop Lim, Kwan,Bhunia, Arun K.,Ladisch, Michael,Bashir, Rashid Royal Society of Chemistry 2006 Lab on a chip Vol.6 No.7

        <P>In this study, we demonstrated a micro-fluidic system with multiple functions, including concentration of bacteria using dielectrophoresis (DEP) and selective capture using antibody recognition, resulting in a high capture efficiency of bacterial cells. The device consisted of an array of oxide covered interdigitated electrodes on a flat silicon substrate and a ∼16 µm high and ∼260 µm wide micro-channel within a PDMS cover. For selective capture of <I>Listeria monocytogenes</I> from the samples, the channel surface was functionalized with a biotinylated BSA–streptavidin–biotinylated monoclonal antibody sandwich structure. Positive DEP (at 20 V<SUB>pp</SUB> and 1 MHz) was used to concentrate bacterial cells from the fluid flow. DEP could collect ∼90% of the cells in a continuous flow at a flow rate of 0.2 µl min<SUP>−1</SUP> into the micro-channel with concentration factors between 10<SUP>2</SUP>–10<SUP>3</SUP>, in sample volumes of 5–20 µl. A high flow rate of 0.6 µl min<SUP>−1</SUP> reduced the DEP capture efficiency to ∼65%. Positive DEP attracts cells to the edges of the electrodes where the field gradient is the highest. Cells concentrated by DEP were captured by the antibodies immobilized on the channel surface with efficiencies of 18 to 27% with bacterial cell numbers ranging from 10<SUP>1</SUP> to 10<SUP>3</SUP> cells. It was found that DEP operation in our experiments did not cause any irreversible damage to bacterial cells in terms of cell viability. In addition, increased antigen expression (antigens to C11E9 monoclonal antibody) on cell membranes was observed following the exposure to DEP.</P> <P>Graphic Abstract</P><P>Bacterial cells were concentrated by positive dielectrophoresis. Target cells were selectively captured by specific antibodies immobilized on the channel surface. <IMG SRC='http://pubs.rsc.org/services/images/RSCpubs.ePlatform.Service.FreeContent.ImageService.svc/ImageService/image/GA?id=b607061m'> </P>

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼