RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Estrogen replacement is protective to the effect of in vitro hypoxia on female rabbit bladder and pelvic floor contractile response

        Amy D. Dobberfuhl,Catherine Schuler,Robert E. Leggett,Elise J.B. De,Robert M. Levin 대한비뇨의학회 2020 Investigative and Clinical Urology Vol.61 No.4

        Purpose: To explore the effect of estrogen replacement on pelvic floor and bladder contractile response to electrical field stimulation, following in vitro hypoxia in an animal model of surgical menopause. Materials and Methods: Twelve female adult rabbits were divided into three groups: control, ovariectomy, and ovariectomy with estradiol replacement. At 4 weeks animals were euthanized. Bladder, coccygeus, and pubococcygeus were isolated. Tissues were equilibrated with oxygenated Tyrodes containing glucose and stimulated with electrical field stimulation. Tissues were then stimulated under hypoxic conditions for 1 hour using nitrogenated Tyrodes without glucose. Tissues were then re-oxygenated for 2 hours and stimulated. Results: Pelvic floor required 10 times the stimulation duration (power) to achieve maximum contraction at 2 g baseline tension (10 ms duration) when compared to bladder (1 ms duration). Maximal tension generated was significantly greater for bladder than pelvic floor. Coccygeus and pubococcygeus were significantly less sensitive to the effects of hypoxia and had stable contractile response to field stimulation throughout the hour of hypoxia. Hypoxia resulted in progressive and rapid decline of bladder contractile strength. Following hypoxia, pelvic floor contractile recovery was superior to bladder. Improvement in the contractile response of both bladder and pelvic floor, during the period of post-hypoxia re-oxygenation, was significantly greater in ovariectomy animals treated with estradiol replacement. Conclusions: Replacement of estradiol at time of ovariectomy reduced oxidative stress on tissue and was protective to the effects of hypoxia on pelvic floor and bladder contractile function.

      • KCI등재

        Noxious electrical stimulation of the pelvic floor and vagina induces transient voiding dysfunction in a rabbit survival model of pelvic floor dystonia

        Amy D. Dobberfuhl,Sara Spettel,Catherine Schuler,Robert M. Levin,Andrew H. Dubin,Elise J.B. De 대한비뇨의학회 2015 Investigative and Clinical Urology Vol.56 No.12

        Purpose: Existing data supports a relationship between pelvic floor dysfunction and lower urinary tract symptoms. We developed a survival model of pelvic floor dysfunction in the rabbit and evaluated cystometric (CMG), electromyographic (EMG) and ambulatory voiding behavior. Materials and Methods: Twelve female adult virgin rabbits were housed in metabolic cages to record voiding and defecation. Anesthetized CMG/EMG was performed before and after treatment animals (n=9) received bilateral tetanizing needle stimulation to the pubococcygeous (PC) muscle and controls (n=3) sham needle placement. After 7 days all animals were subjected to tetanizing transvaginal stimulation and CMG/EMG. After 5 days a final CMG/EMG was performed. Results: Of rabbits that underwent needle stimulation 7 of 9 (78%) demonstrated dysfunctional CMG micturition contractions versus 6 of 12 (50%) after transvaginal stimulation. Needle stimulation of the PC musculature resulted in significant changes in: basal CMG pressure, precontraction pressure change, contraction pressure, interval between contractions and postvoid residual; with time to 3rd contraction increased from 38 to 53 minutes (p=0.008 vs. prestimulation). Vaginal noxious stimulation resulted in significant changes in: basal CMG pressure and interval between contractions; with time to 3rd contraction increased from 37 to 46 minutes (p=0.008 vs. prestimulation). Changes in cage parameters were primarily seen after direct needle stimulation. Conclusions: In a majority of animals, tetanizing electrical stimulation of the rabbit pelvic floor resulted in voiding changes suggestive of pelvic floor dysfunction as characterized by a larger bladder capacity, longer interval between contractions and prolonged contraction duration.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼