RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Comparing dusting and fragmenting efficiency using the new SuperPulsed thulium fiber laser versus a 120 W Holmium:YAG laser

        Ben H. Chew,구교철,Abdulghafour Halawani,Colin J. Lundeen,Bodo E. Knudsen,Wilson R. Molina 대한비뇨의학회 2023 Investigative and Clinical Urology Vol.64 No.3

        Purpose: Holmium:YAG laser lithotripsy requires high amperage power and has an upper limit of frequency and a minimal fiber size. The technology utilizing thulium-doped fiber offers low pulse energy settings and high pulse frequencies up to 2,400 Hz. We compared the novel SuperPulsed thulium fiber laser (SOLTIVE™; Olympus) to a commercially available 120 W Ho:YAG laser. Materials and Methods: Bench-top testing was conducted with 125 mm3 standardized BegoStones (Bego USA). Time to ablate the stone into particles <1 mm was recorded for efficiency calculations. Finite energy was delivered, and resulting particle sizes were measured to determine fragmentation (0.5 kJ) and dusting (2 kJ) efficiencies. Remaining mass or number of fragments were measured to compare efficacy. Results: SOLTIVE™ was faster at ablating stones to particles <1 mm (2.23±0.22 mg/s, 0.6 J 30 Hz short pulse) compared to Ho:YAG laser (1.78±0.44 mg/s, 0.8 J 10 Hz short pulse) (p<0.001). Following 0.5 kJ of energy in fragmentation testing, fewer particles >2 mm remained using SOLTIVE™ than Ho:YAG laser (2.10 vs. 7.20 fragments). After delivering 2 kJ, dusting (1.05±0.08 mg/s) was faster using SOLTIVE™ (0.1 J 200 Hz short pulse) than 120 W 0.46±0.09 mg/s (0.3 J 70 Hz Moses) (p=0.005). SOLTIVE™ (0.1 J 200 Hz) produced more dust particles <0.5 mm (40%) compared to 24% produced by the P120 W laser at 0.3 J 70 Hz Moses and 14% at 0.3 J 70 Hz long pulse (p=0.015). Conclusions: The efficacy of SOLTIVE™ is superior to the 120 W Ho:YAG laser by producing smaller dust particles and fewer fragments. Further studies are warranted.

      • KCI등재

        Predictors of urosepsis in struvite stone patients after percutaneous nephrolithotomy

        Justin Y.H. Chan,Victor K.F. Wong,Julie Wong,Ryan F. Paterson,Dirk Lange,Ben H. Chew,Kymora B. Scotland 대한비뇨의학회 2021 Investigative and Clinical Urology Vol.62 No.2

        Purpose: This study aims to identify clinical factors that may predispose struvite stone patients to urosepsis following percutaneous nephrolithotomy (PCNL). Materials and Methods: A retrospective review was conducted on patients who received PCNL for struvite stones. The Systemic Inflammatory Response Syndrome (SIRS) criteria and quick-Sepsis Related Organ Failure Assessment (q-SOFA) criteria were used to identify patients who were at an increased risk for urosepsis. Statistical analysis was performed using Fisher's exactness test, Wilcoxon rank test, and logistic regression. Results: Chart review identified 99 struvite stone patients treated with PCNL. Post-operatively, 40 patients were SIRS positive (≥2 criteria) and/or q-SOFA positive (score ≥2). Using SIRS as an approximation for urosepsis, longer operative times (p<0.001), higher pre-operative white blood cell counts (p=0.01), greater total stone surface area (p<0.0001), and pre-operative stenting (OR, 5.75; p=0.01) were identified as independent risk factors for urosepsis. Multivariate analysis demonstrated pre-operative stenting (OR, 1.46; p=0.01) to be a risk factor. With q-SOFA, univariable analysis found that antibiotic use within 3 months prior to a PCNL (OR, 4.44; p=0.04), medical comorbidities (OR, 4.80; p=0.02), longer operative times (p<0.001), lengthier post-operative hospitalization (p<0.01), and greater total stone surface area (p<0.0001) were risk factors for urosepsis. Multivariate analysis revealed that bladder outlet obstruction (OR, 2.74; p<0.003) and pre-operative stenting (OR, 1.27; p=0.01) significantly increased odds of being q-SOFA positive. Conclusions: Several risk factors for urosepsis following PCNL for struvite stones have been identified. These risk factors should be taken into consideration in peri-operative care to mitigate the risks of urosepsis.

      • KCI등재

        Controversies associated with ureteral access sheath placement during ureteroscopy

        Victor K.F. Wong,Khatereh Aminoltejari,Khaled Almutairi,Dirk Lange,Ben H. Chew 대한비뇨의학회 2020 Investigative and Clinical Urology Vol.61 No.5

        The use of ureteral access sheaths (UAS) is common practice during routine flexible ureteroscopy procedures. However, debates and concerns continue amongst endourologists on routine UAS placement. UAS placement allows for multiple passages of the ureteroscope, decreases intrarenal pressure, and may improve stone-free rates. However, concerns for the UAS's effectiveness in these claimed benefits and complications related to UAS placement has been documented and investigated by many. In this review, we will discuss the controversies surrounding the placement of UAS during ureteroscopy.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼