RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재후보

        Seismic behavior of soft storey mid-rise steel frames with randomly distributed masonry infill

        Shahriar Quayyum,M. Shahria Alam,Ahmad Rteil 국제구조공학회 2013 Steel and Composite Structures, An International J Vol.14 No.6

        In this study, the effect of presence and distribution of masonry infill walls on the mid-rise steel frame structures having soft ground storey was evaluated by implementing finite element (FE) methods. Masonry infill walls were distributed randomly in the upper storey keeping the ground storey open without any infill walls, thus generating the worst case scenario for seismic events. It was observed from the analysis that there was an increase in the seismic design forces, moments and base shear in presence of randomly distributed masonry infill walls which underlines that these design values need to be amplified when designing a mid-rise soft ground storey steel frame with randomly distributed masonry infill. In addition, it was found that the overstrength related force modification factor increased and the ductility related force modification factor decreased with the increase in the amount of masonry infilled bays and panels. These must be accounted for in the design of mid-rise steel frames. Based on the FE analysis results on two mid-rise steel frames, design equations were proposed for determining the over strength and the ductility related force modification factors. However, it was recommended that these equations to be generalized for other steel frame structure systems based on an extensive analysis.

      • KCI등재

        Fire performance curves for unprotected HSS steel column

        M. Shahria Alam,A.H.M. Muntasir Billah,Shahriar Quayyum,Mahmud Ashraf,A.N.M. Rafi,Ahmad Rteil 국제구조공학회 2013 Steel and Composite Structures, An International J Vol.15 No.6

        The behaviour of steel column at elevated temperature is significantly different than that atambient temperature due to its changes in the mechanical properties with temperature. Reported literaturesuggests that steel column may become vulnerable when exposed to fire condition, since its strength andcapacity decrease rapidly with temperature. The present study aims at investigating the lateral load resistanceof non-insulated steel columns under fire exposure through finite element analysis. The studied parametersinclude moment-rotation behaviour, lateral load-deflection behaviour, stiffness and ductility of columns atdifferent axial load levels. It was observed that when the temperature of the column was increased, there wasa significant reduction in the lateral load and moment capacity of the non-insulated steel columns. Moreover,it was noted that the stiffness and ductility of steel columns decreased sharply with the increase intemperature, especially for temperatures above 400°C. In addition, the lateral load capacity and the momentcapacity of columns were plotted against fire exposure time, which revealed that in fire conditions, thenon-insulated steel columns experience substantial reduction in lateral load resistance within 15 minutes offire exposure.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼