http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
적층형 4-BAR 메커니즘을 이용한 평면형 메니퓰레이터
이호열(Hoyul Lee),최영진(Youngjin Choi) 제어로봇시스템학회 2010 제어·로봇·시스템학회 논문지 Vol.16 No.5
This paper proposes a new planar robotic manipulator using stackable 4-BAR mechanisms for various applications. The proposed manipulator has an advantage that we can separate the driving actuators from a robotic manipulator. By separating actuators from the manipulator, we are able to separate the electrical component such as electrical wiring from the mechanical linkage/joint components in the robotic manipulator. Also, we suggest the kinematic analysis of the proposed manipulator which is composed of input mechanisms, multiple 4-BAR mechanisms and output mechanisms. Finally, we suggest numerical simulations to show the effectiveness of the proposed manipulator.
저 전력 블루투스 기반으로 의료데이터 전송 시 통신 거리와 연동 장치의 수가 데이터 손실률에 미치는 영향
박영상,손병진,손재범,이호열,정유수,송찬호,정의성,Park, Young-Sang,Son, ByeongJin,Son, Jaebum,Lee, Hoyul,Jeong, Yoosoo,Song, Chanho,Jung, Euisung 대한의용생체공학회 2021 의공학회지 Vol.42 No.6
Recently, the market for personal health care and medical devices based on Bluetooth Low Energy(BLE) has grown rapidly. BLE is being used in various medical data communication devices based on low power consumption and universal compatibility. However, since data errors occurring in the transmission of medical data can lead to medical accidents, it is necessary to analyze the causes of errors and study methods to reduce data error. In this paper, the minimum communication speed to be used in medical devices was set to at least 800 byte/sec based on the wireless electrocardiography regulations of the Ministry of Food and Drug Safety. And the data loss rate was tested when data was transmitted at a speed higher than 800 byte/sec. The factors that cause communication data error were classified, and the relationship between each factor and the data error rate was analyzed through experiments. When there were two or more activated peripherals connected to the central, data error occurred due to channel hopping and bottleneck, and the data error rate increased in proportion to the communication distance and the number of activated peripherals. Through this experiment, when the BLE is used in a medical device that intermittently transmits biosignal data, the risk of a medical accident is predicted to be low if the number of peripherals is 3 or less. But, it was determined that BLE would not be suitable for the development of a biosignal measuring device that must be continuously transmitted in real time, such as an electrocardiogram.