    Hemodynamic Analysis of Implanted Medical Devices for Advanced Treatment Planning in Cardiovascular Diseases Using Computational Fluid Dynamics

    한글로보기

    https://www.riss.kr/link?id=T17198813

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
      • URL 복사
    • 오류접수
    인용문이 복사되었습니다.

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    Cardiovascular diseases remain the leading cause of mortality worldwide, necessitating innovative treatment and prevention strategies. Implantable medical devices, such as artificial valves, pacemakers, and coronary stents, play a vital role in managing these conditions. However, hemodynamic changes induced by these devices have not been fully understood. This study applies computational fluid dynamics (CFD) to investigate two in cardiovascular treatment: (1) hemodynamic changes associated with percutaneous pulmonary valve implantation (PPVI) and their correlation with clinical outcomes, and (2) the effects of slip boundary conditions on thrombosis-related hemodynamic factors in pacemaker leads and coronary stents. In the first part, patient-specific CFD analysis was performed for nine Tetralogy of Fallot patients before and after PPVI. The analysis demonstrated approximately 60% reductions in vorticity, backward flow, and energy dissipation post-PPVI. Additionally, correlations were observed between pulmonary artery hemodynamics and clinical indices such as right ventricular end-diastolic volume index (RVEDVi), as well as among various hemodynamic CFD parameters. These findings demonstrate CFD's potential to enhance the evaluation of PPVI effectiveness and guide clinical decision- making. In the second part, a venous anatomical model with a pacemaker lead and a coronary artery model with a stent were developed to observe hemodynamic changes related to thrombosis. Slip surfaces were then applied to the surfaces of the implanted medical devices, and their effects on hemodynamics under physiological conditions were quantitatively analyzed. Slip surfaces improved hemodynamics, increasing wall shear stress (WSS) by up to 1.17-fold in the pacemaker model and reducing low WSS regions by 52% in the stent model. These results suggest that slip surfaces could mitigate complications and enhance device longevity. This study underscores the potential of CFD in optimizing cardiovascular medical device performance, offering valuable insights for advancing treatment strategies and improving the safety and efficacy of implantable devices under physiological conditions.
    번역하기

    Cardiovascular diseases remain the leading cause of mortality worldwide, necessitating innovative treatment and prevention strategies. Implantable medical devices, such as artificial valves, pacemakers, and coronary stents, play a vital role in managi...

    Cardiovascular diseases remain the leading cause of mortality worldwide, necessitating innovative treatment and prevention strategies. Implantable medical devices, such as artificial valves, pacemakers, and coronary stents, play a vital role in managing these conditions. However, hemodynamic changes induced by these devices have not been fully understood. This study applies computational fluid dynamics (CFD) to investigate two in cardiovascular treatment: (1) hemodynamic changes associated with percutaneous pulmonary valve implantation (PPVI) and their correlation with clinical outcomes, and (2) the effects of slip boundary conditions on thrombosis-related hemodynamic factors in pacemaker leads and coronary stents. In the first part, patient-specific CFD analysis was performed for nine Tetralogy of Fallot patients before and after PPVI. The analysis demonstrated approximately 60% reductions in vorticity, backward flow, and energy dissipation post-PPVI. Additionally, correlations were observed between pulmonary artery hemodynamics and clinical indices such as right ventricular end-diastolic volume index (RVEDVi), as well as among various hemodynamic CFD parameters. These findings demonstrate CFD's potential to enhance the evaluation of PPVI effectiveness and guide clinical decision- making. In the second part, a venous anatomical model with a pacemaker lead and a coronary artery model with a stent were developed to observe hemodynamic changes related to thrombosis. Slip surfaces were then applied to the surfaces of the implanted medical devices, and their effects on hemodynamics under physiological conditions were quantitatively analyzed. Slip surfaces improved hemodynamics, increasing wall shear stress (WSS) by up to 1.17-fold in the pacemaker model and reducing low WSS regions by 52% in the stent model. These results suggest that slip surfaces could mitigate complications and enhance device longevity. This study underscores the potential of CFD in optimizing cardiovascular medical device performance, offering valuable insights for advancing treatment strategies and improving the safety and efficacy of implantable devices under physiological conditions.

    더보기

    목차 (Table of Contents)

    • 1. Introduction 1
    • 2. Patient-specific cardiovascular modeling and simulation 4
    • 2.1 Flow solvers 4
    • 2.1.1 Governing equations and numerical methods 4
    • 2.1.2 Slip boundary condition 5
    • 1. Introduction 1
    • 2. Patient-specific cardiovascular modeling and simulation 4
    • 2.1 Flow solvers 4
    • 2.1.1 Governing equations and numerical methods 4
    • 2.1.2 Slip boundary condition 5
    • 2.2 Patient-specific anatomic modeling 8
    • 2.3 Post-processing for hemodynamic analysis 11
    • 2.3.1 Wall shear stress 11
    • 2.3.2 Residence time 11
    • 2.3.3 Vorticity 12
    • 2.3.4 Energy dissipation 12
    • 3. Hemodynamics analysis on implanted medical devices 13
    • 3.1 Pulmonary artery model before and after PPVI 13
    • 3.1.1 Anatomic modeling 13
    • 3.1.2 Simulation details 14
    • 3.1.3 Results & Discussion 15
    • 3.2 Venous model with pacemaker lead 22
    • 3.2.1 Anatomic modeling 22
    • 3.2.2 Simulation details 23
    • 3.2.3 Results & Discussion 25
    • 3.3 Coronary artery model with a stent 29
    • 3.3.1 Anatomic modeling 29
    • 3.3.2 Simulation details 30
    • 3.3.3 Results & Discussion 32
    • 4. Discussion 36
    • 5. Conclusion 40
    • 6. References 41
    • 7. Acknowledgments 49
    • 8. Appendix 50
    더보기

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    이 자료와 함께 이용한 RISS 자료

    나만을 위한 추천자료

    해외이동버튼