RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      CIE 광원에서 시행한 farnsworth-munsell 100 hue test의 새로운 분석 = A new analysis of the farnsworth-munsell 100 hue test under CIE illuminants

      한글로보기

      https://www.riss.kr/link?id=T14495726

      • 저자
      • 발행사항

        논산 : 건양대학교, 2017

      • 학위논문사항

        학위논문(박사) -- 건양대학교 일반대학원 , 안경광학과 , 2017

      • 발행연도

        2017

      • 작성언어

        한국어

      • 주제어
      • KDC

        555.611 판사항(6)

      • DDC

        681.411 판사항(23)

      • 발행국(도시)

        충청남도

      • 형태사항

        v, 115장 : 천연색삽화, 도표 ; 26 cm

      • 일반주기명

        지도교수: 최은정
        권말부록: Color characteristics for the each cap under D65 in (A), (B), and (C) 등
        참고문헌: 장 84-89

      • 소장기관
        • 건양대학교 명곡도서관 소장기관정보
        • 국립중앙도서관 국립중앙도서관 우편복사 서비스
      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

      Purpose: This study was designed to analyze color characteristics of 85 caps and evaluate color perception by using FM 100 hue test under CIE illuminant D65, TL84, and A. Methods: 85 caps were measured to analyze color characteristics (x, y, L*, a*, and b*) with UV-2450 UV-VIS spectrophotometer (Shimadzu, Japan) according to types of light source. For clinical trial, 42 subjects aged 25.24±3.15 years with corrected visual acuity 0.8 or above and no color blindness participated in this study. Light booth was used to create standard luminous environment, and FM 100 hue test was conducted to evaluate changes of color perception under D65, TL84, and A. Results were objectively calculated by ES and TES, and the higher ES and TES indicated decline in color perception.
      Results: In xy coordinates, the distance between caps constituting group Ⅲ was not uniform. Metamerism index representing the color difference of the adjacent caps in the other two light source was the smallest between TL84 and A. Color perception according to types of light source were significantly different among D65, TL84, and A. The average of TES was higher in order of A, TL84, and D65, so the most dramatic decline in color perception was occurred in A (p<0.001). When comparing with color perception according to color group in each light source, significant decline in color perception occurred in group Ⅲ under D65, in group Ⅱ under TL84, both group Ⅱ and group Ⅲ under A (p<0.001). ES of A was significantly higher than those of D65 and TL84 in group Ⅰ, Ⅲ, and Ⅳ. ES of both A and TL84 were significantly higher than that of D65 (p<0.001). Conclusions: This study suggested that color appearance of caps and color perception in FM 100 hue test changed according to types of light source. Opticians need to help customers choose the color of their product correctly when they select and judge the colors of the various products under the illumination which does not show the color perception error.
      번역하기

      Purpose: This study was designed to analyze color characteristics of 85 caps and evaluate color perception by using FM 100 hue test under CIE illuminant D65, TL84, and A. Methods: 85 caps were measured to analyze color characteristics (x, y, L*, a*, a...

      Purpose: This study was designed to analyze color characteristics of 85 caps and evaluate color perception by using FM 100 hue test under CIE illuminant D65, TL84, and A. Methods: 85 caps were measured to analyze color characteristics (x, y, L*, a*, and b*) with UV-2450 UV-VIS spectrophotometer (Shimadzu, Japan) according to types of light source. For clinical trial, 42 subjects aged 25.24±3.15 years with corrected visual acuity 0.8 or above and no color blindness participated in this study. Light booth was used to create standard luminous environment, and FM 100 hue test was conducted to evaluate changes of color perception under D65, TL84, and A. Results were objectively calculated by ES and TES, and the higher ES and TES indicated decline in color perception.
      Results: In xy coordinates, the distance between caps constituting group Ⅲ was not uniform. Metamerism index representing the color difference of the adjacent caps in the other two light source was the smallest between TL84 and A. Color perception according to types of light source were significantly different among D65, TL84, and A. The average of TES was higher in order of A, TL84, and D65, so the most dramatic decline in color perception was occurred in A (p<0.001). When comparing with color perception according to color group in each light source, significant decline in color perception occurred in group Ⅲ under D65, in group Ⅱ under TL84, both group Ⅱ and group Ⅲ under A (p<0.001). ES of A was significantly higher than those of D65 and TL84 in group Ⅰ, Ⅲ, and Ⅳ. ES of both A and TL84 were significantly higher than that of D65 (p<0.001). Conclusions: This study suggested that color appearance of caps and color perception in FM 100 hue test changed according to types of light source. Opticians need to help customers choose the color of their product correctly when they select and judge the colors of the various products under the illumination which does not show the color perception error.

      더보기

      목차 (Table of Contents)

      • 제1장 서 론 1
      • 제1절 이론적 배경 1
      • 1. CIE 광원 1
      • 2. 상관색온도와 연색지수 3
      • 3. CIE 표색계 4
      • 제1장 서 론 1
      • 제1절 이론적 배경 1
      • 1. CIE 광원 1
      • 2. 상관색온도와 연색지수 3
      • 3. CIE 표색계 4
      • 4. 색채 지각과 조건등색 5
      • 5. Farnsworth-Munsell 100 hue test 9
      • 제2절 연구목적 14
      • 제2장 연구대상 및 방법 16
      • 제1절 연구대상 16
      • 1. 임상연구대상 16
      • 제2절 연구방법 17
      • 1. 조명부스와 광원 17
      • 2. FM 100 hue test 캡의 색좌표 측정 22
      • 3. 캡의 색좌표를 이용한 계산 23
      • 4. FM 100 hue test의 임상실험 27
      • 5. 각 캡에 대한 error score‘의 95% 신뢰구간 계산 29
      • 제3절 자료처리 및 분석 30
      • 제3장 결 과 30
      • 제1절 광원의 종류에 따른 FM 100 hue test 캡의 색 특성 31
      • 1. 색좌표 x, y 31
      • 2. 색좌표 L*, a*, b* 36
      • 제2절 FM 100 hue test의 임상데이터 43
      • 1. 광원의 종류에 따른 total error score 43
      • 2. 동일 광원 내에서 캡과 색상 그룹에 따른 error score 45
      • 3. 동일 색상 그룹 내에서 광원의 종류에 따른 error score 59
      • 4. 두 광원 사이에서 error score의 차이 67
      • 5. 광원의 종류에 따른 error score‘ 의 95% 신뢰구간 73
      • 제 4장 고 찰 75
      • 제 5장 결 론 82
      • 참고문헌 84
      • 초 록 90
      • 부 록 92
      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼