RISS 학술연구정보서비스

검색

인기 검색어

    다국어 입력

    http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

    변환된 중국어를 복사하여 사용하시면 됩니다.

    예시)
    • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
    • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
    닫기

    임플란트 고정성 보철물 제작에 사용되는 수종 교합인기 술식의 정확성에 관한 연구 = Evaluation of the accuracy of different bite registration techniques for implant fixed prostheses

    한글로보기

    https://www.riss.kr/link?id=T14016638

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
      • URL 복사
    • 오류접수
    인용문이 복사되었습니다.

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    The fabrication of implant prosthesis is carried out through several steps. Among them, bite registration is the most basic and important process. Studies have been done to evaluate the accuracy of bite registration. but research has not been reported which was related to the implant bite registration. Therefore, this study determined to evaluate the accuracy of different bite registration techniques for implant fixed prostheses with 3D files
    Implant fixtures were placed on the mandibular right second premolar, first molar, second molar in the polyurethane model. Maxillary and mandibular polyurethane models were mounted on a articulator. This polyurethane models were assumed to a patient. Healing abutments, temporary abutments were used for HA, HP, HB group (n=15) and TA, TP, TB group (n=15) each. Aluwax, Pattern Resin and Blu-Mousse were used as bite registration materials. For group BC using bite impression coping, impression taking and bite registration were done at the same time. These models were attached to the articulators. Scan bodies were connected to the fixtures and lab analogs of the casts. All the casts were scanned with a model scanner. Center of the superior surface of the #46 site scan body and mesiopalatal cusp tip of #16 were set as a reference point. The distance measured between the reference point in the three-dimensional files
    The smallest error was showed on the group using temporary abutments and polyvinylsiloxane bite material (group TB) and the group using bite impression coping (group BC). The largest error showed on the group using healing abutment and Pattern Resin (group HP). There was statistically difference between group TB, BC and group HP (p=.001). This experiment could not take into account the biological factor and dimensional change of impression materials, dental stone. Therefore, additional studies are needed considering these factors.
    번역하기

    The fabrication of implant prosthesis is carried out through several steps. Among them, bite registration is the most basic and important process. Studies have been done to evaluate the accuracy of bite registration. but research has not been reported...

    The fabrication of implant prosthesis is carried out through several steps. Among them, bite registration is the most basic and important process. Studies have been done to evaluate the accuracy of bite registration. but research has not been reported which was related to the implant bite registration. Therefore, this study determined to evaluate the accuracy of different bite registration techniques for implant fixed prostheses with 3D files
    Implant fixtures were placed on the mandibular right second premolar, first molar, second molar in the polyurethane model. Maxillary and mandibular polyurethane models were mounted on a articulator. This polyurethane models were assumed to a patient. Healing abutments, temporary abutments were used for HA, HP, HB group (n=15) and TA, TP, TB group (n=15) each. Aluwax, Pattern Resin and Blu-Mousse were used as bite registration materials. For group BC using bite impression coping, impression taking and bite registration were done at the same time. These models were attached to the articulators. Scan bodies were connected to the fixtures and lab analogs of the casts. All the casts were scanned with a model scanner. Center of the superior surface of the #46 site scan body and mesiopalatal cusp tip of #16 were set as a reference point. The distance measured between the reference point in the three-dimensional files
    The smallest error was showed on the group using temporary abutments and polyvinylsiloxane bite material (group TB) and the group using bite impression coping (group BC). The largest error showed on the group using healing abutment and Pattern Resin (group HP). There was statistically difference between group TB, BC and group HP (p=.001). This experiment could not take into account the biological factor and dimensional change of impression materials, dental stone. Therefore, additional studies are needed considering these factors.

    더보기

    목차 (Table of Contents)

    • 1. 서론
    • 2. 연구 재료 및 방법
    • 3. 연구 결과
    • 4. 총괄 및 고찰
    • 5. 결론
    • 1. 서론
    • 2. 연구 재료 및 방법
    • 3. 연구 결과
    • 4. 총괄 및 고찰
    • 5. 결론
    더보기

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    이 자료와 함께 이용한 RISS 자료

    나만을 위한 추천자료

    해외이동버튼