    가공 송전선로에서 발생하는 극저주파 전자계의 국내 현장 여건을 고려한 측정 방법에 관한 연구 = A Study on Measurement Methods of Extremely Low Frequency EMF from Overhead Transmission Lines Considering Domestic Field Conditions

    한글로보기

    https://www.riss.kr/link?id=A110174746

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
    • 오류접수
    인용문이 복사되었습니다.

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    Exposure to extremely low frequency (ELF) electromagnetic fields (EMFs) from power transmission and distribution facilities has gained increasing attention with rising power demand driven by artificial intelligence (AI). This study proposes a practical EMF measurement method suitable for domestic power facility environments in Korea. Field measurements were conducted on 345 kV and 154 kV overhead transmission lines and 22.9 kV distribution lines based on ICNIRP guidelines and international standards IEC 62110 and IEEE Std 644. Measurements were performed at the maximum sag point at different lateral distances and representative heights. The results show that EMF levels were highest directly beneath the conductors and decreased rapidly with distance, while all measured values remained well below domestic exposure limits.
    번역하기

    Exposure to extremely low frequency (ELF) electromagnetic fields (EMFs) from power transmission and distribution facilities has gained increasing attention with rising power demand driven by artificial intelligence (AI). This study proposes a practica...

    Exposure to extremely low frequency (ELF) electromagnetic fields (EMFs) from power transmission and distribution facilities has gained increasing attention with rising power demand driven by artificial intelligence (AI). This study proposes a practical EMF measurement method suitable for domestic power facility environments in Korea. Field measurements were conducted on 345 kV and 154 kV overhead transmission lines and 22.9 kV distribution lines based on ICNIRP guidelines and international standards IEC 62110 and IEEE Std 644. Measurements were performed at the maximum sag point at different lateral distances and representative heights. The results show that EMF levels were highest directly beneath the conductors and decreased rapidly with distance, while all measured values remained well below domestic exposure limits.

    더보기

    동일학술지(권/호) 다른 논문

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    이 자료와 함께 이용한 RISS 자료

    나만을 위한 추천자료

    해외이동버튼